Correlative cryo-qSTEM-CL imaging in a SEM

  1. 1.
    SYSNO ASEP0495552
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    Zařazení RIVNení vybrán druh dokumentu
    NázevCorrelative cryo-qSTEM-CL imaging in a SEM
    Tvůrce(i) Skoupý, Radim (UPT-D) RID, ORCID, SAI
    Krzyžánek, Vladislav (UPT-D) RID, ORCID, SAI
    Celkový počet autorů2
    Zdroj.dok.19th International Microscopy Congress (IMC19). Book of Abstracts.. - Sydney : LMA, 2018
    Poč.str.1 s.
    Forma vydáníTištěná - P
    AkceInternational Microscopy Congress (IMC19) /19./
    Datum konání09.09.2018 - 14.09.2018
    Místo konáníSydney
    ZeměAU - Austrálie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.AU - Austrálie
    Klíč. slovacorrelative imaging ; quantitative imaging ; Monte Carlo
    Vědní obor RIVJA - Elektronika a optoelektronika, elektrotechnika
    Obor OECDNano-materials (production and properties)
    CEPGA17-15451S GA ČR - Grantová agentura ČR
    LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    AnotaceNowadays, a correlative microscopy of several signals is one of the main topics in the electron microscopy field. In some studies, a localization, distribution and density of light emitting labels or particles in a sample is important. Unfortunately, not all light emitting structures are possible to be imaged at room temperature. Very fine particles like quantum dots with diameter in terms of nm are recognizable only at very low temperatures and with appropriate anticontamination shielding, because a contamination layer of hydrocarbon deposits can disturb whole measuring at the first electron beam scan. Qualitative imaging can be changed to quantitative by using Monte Carlo (MC) simulations of samples, with known composition and density, which can bring a new dimension to thin samples imaging by STEM (Scanning Transmission Electron Microscopy). Recalculation of calibrated images via MC gives the information about the local thickness of the sample and total mass of the imaged particle with high precision (approach published in was used). This information can be compared with local cathodoluminescence (CL) activity or quantitative imaging in backscattered electrons.