Počet záznamů: 1  

Reduction of stored-particle background by a magnetic pulse method at the KATRIN experiment

  1. 1.
    SYSNO ASEP0494427
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevReduction of stored-particle background by a magnetic pulse method at the KATRIN experiment
    Tvůrce(i) Arenz, M. (DE)
    Baek, W. -J. (DE)
    Bauer, S. (DE)
    Beck, M. (DE)
    Beglarian, A. (DE)
    Dragoun, Otokar (UJF-V) RID, SAI
    Kovalík, Alojz (UJF-V) RID, ORCID, SAI
    Lebeda, Ondřej (UJF-V) RID, ORCID, SAI
    Ryšavý, Miloš (UJF-V) RID, ORCID, SAI
    Sentkerestiová, Jana (UJF-V) SAI
    Suchopár, Martin (UJF-V)
    Vénos, Drahoslav (UJF-V) RID, SAI, ORCID
    Celkový počet autorů129
    Číslo článku778
    Zdroj.dok.European Physical Journal C. - : Springer - ISSN 1434-6044
    Roč. 78, č. 9 (2018)
    Poč.str.16 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaKATRIN experiment ; neutrino mass detection ; magnetic pulse method
    Vědní obor RIVBF - Elementární částice a fyzika vys. energií
    Obor OECDParticles and field physics
    CEPLM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LTT18021 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000445683400006
    EID SCOPUS85053933839
    DOI10.1140/epjc/s10052-018-6244-8
    AnotaceThe KATRIN experiment aims to determine the effective electron neutrino mass with a sensitivity of 0.2 eV/c(2) (% 90 CL) by precision measurement of the shape of the tritium beta-spectrum in the endpoint region. The energy analysis of the decay electrons is achieved by a MAC-E filter spectrometer. A common background source in this setup is the decay of short-lived isotopes, such as Rn-219 and Rn-220, in the spectrometer volume. Active and passive countermeasures have been implemented and tested at the KATRIN main spectrometer. One of these is the magnetic pulse method, which employs the existing air coil system to reduce the magnetic guiding field in the spectrometer on a short timescale in order to remove low-and high-energy stored electrons. Here we describe the working principle of this method and present results from commissioning measurements at the main spectrometer. Simulations with the particle-tracking software KASSIOPEIA were carried out to gain a detailed understanding of the electron storage conditions and removal processes.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.