Počet záznamů: 1  

Calibration of high voltages at the ppm level by the difference of Kr-83m conversion electron lines at the KATRIN experiment

  1. 1.
    SYSNO ASEP0490014
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCalibration of high voltages at the ppm level by the difference of Kr-83m conversion electron lines at the KATRIN experiment
    Tvůrce(i) Arenz, M. (DE)
    Baek, W. -J. (DE)
    Beck, M. (DE)
    Beglarian, A. (DE)
    Behrens, J. (DE)
    Dragoun, Otokar (UJF-V) RID, SAI
    Kovalík, Alojz (UJF-V) RID, ORCID, SAI
    Lebeda, Ondřej (UJF-V) RID, ORCID, SAI
    Ryšavý, Miloš (UJF-V) RID, ORCID, SAI
    Sentkerestiová, Jana (UJF-V) SAI
    Suchopár, Martin (UJF-V)
    Vénos, Drahoslav (UJF-V) RID, SAI, ORCID
    Celkový počet autorů127
    Číslo článku368
    Zdroj.dok.European Physical Journal C. - : Springer - ISSN 1434-6044
    Roč. 78, č. 5 (2018)
    Poč.str.7 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaKATRIN ; neutrino ; Kr-83m
    Vědní obor RIVBF - Elementární částice a fyzika vys. energií
    Obor OECDParticles and field physics
    CEPLM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LTT18021 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000432077800004
    EID SCOPUS85046632575
    DOI10.1140/epjc/s10052-018-5832-y
    AnotaceThe neutrino mass experiment KATRIN requires a stability of 3 ppm for the retarding potential at - 18.6 kV of the main spectrometer. To monitor the stability, two custom-made ultra-precise high-voltage dividers were developed and built in cooperation with the German national metrology institute Physikalisch-Technische Bundesanstalt (PTB). Until now, regular absolute calibration of the voltage dividers required bringing the equipment to the specialised metrology laboratory. Here we present a new method based on measuring the energy difference of two Kr-83m conversion electron lines with the KATRIN setup, which was demonstrated during KATRIN's commissioning measurements in July 2017. The measured scale factor M = 1972.449(10) of the high-voltage divider K35 is in agreement with the last PTB calibration 4 years ago. This result demonstrates the utility of the calibration method, as well as the long-term stability of the voltage divider.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2019
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.