Počet záznamů: 1
High resolution Thomson scattering on the COMPASS tokamak - extending edge plasma view and increasing repetition rate
- 1.
SYSNO ASEP 0489514 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název High resolution Thomson scattering on the COMPASS tokamak - extending edge plasma view and increasing repetition rate Tvůrce(i) Bílková, Petra (UFP-V) RID
Böhm, Petr (UFP-V) RID
Aftanas, Milan (UFP-V) RID
Šos, Miroslav (UFP-V) ORCID
Havránek, Aleš (UFP-V) ORCID
Šesták, David (UFP-V) RID
Weinzettl, Vladimír (UFP-V) RID, ORCID
Hron, Martin (UFP-V) RID, ORCID
Pánek, Radomír (UFP-V) RIDČíslo článku C01024 Zdroj.dok. Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
Roč. 13, č. 1 (2018)Poč.str. 10 s. Forma vydání Tištěná - P Akce International Symposium on Laser-Aided Plasma Diagnostics (LAPD2017) /18./ Datum konání 24.09.2017 - 28.09.2017 Místo konání Prague Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova Plasma diagnostics - interferometry ; spectroscopy and imaging ; Trigger concepts and systems (hardware and software) Vědní obor RIV BL - Fyzika plazmatu a výboje v plynech Obor OECD 2.11 Other engineering and technologies CEP GA14-35260S GA ČR - Grantová agentura ČR 8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Institucionální podpora UFP-V - RVO:61389021 UT WOS 000422899200007 EID SCOPUS 85041453963 DOI 10.1088/1748-0221/13/01/C01024 Anotace The Thomson scattering (TS) diagnostic system on the COMPASS tokamak consists of separate collection optics for core and edge plasmas. Till now, the adverse orientation of the viewport available for the edge TS limited the investigated plasma scenarios to those, where H-mode plasma pedestal was possible to be observed. The vacuum vessel port has been recently modified and directed more to the plasma edge. To bridge the time for designing and manufacturing a new lens, the so far used edge TS collection lens was tilted and the fibre bundles rearranged to comply with the new geometry. However, the full potential of the new port is utilized only by the newly designed and manufactured lens. Comparison of performance of the collection lenses before and after the viewport modification is presented. Apart from the edge collection system upgrade, the laser system was extended by two lasers with parameters similar to the original two, thus increasing the repetition rate of the TS system to 120 Hz or allowing to obtain four profiles with tight timing in order to measure fast transient events in the plasma. Pracoviště Ústav fyziky plazmatu Kontakt Vladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975 Rok sběru 2019
Počet záznamů: 1