Počet záznamů: 1  

Fatigue Properties and Biocompatibility of Ti-6A1-4V Alloy after EDM Process for Improved Osteointegration-Comprehensive Research Report

  1. 1.
    SYSNO ASEP0487380
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVZáznam nebyl označen do RIV
    NázevFatigue Properties and Biocompatibility of Ti-6A1-4V Alloy after EDM Process for Improved Osteointegration-Comprehensive Research Report
    Tvůrce(i) Stráský, J. (CZ)
    Janeček, M. (CZ)
    Bačáková, Lucie (FGU-C) RID, ORCID
    Vrátná, J. (CZ)
    Harcuba, P. (CZ)
    Wagner, L. (DE)
    Zdroj.dok.TI-2011: PROCEEDINGS OF THE 12TH WORLD CONFERENCE ON TITANIUM, 3. - Beijing : SCIENCE PRESS BEIJING, 2012 - ISBN 978-7-03-033894-5
    Rozsah strans. 2172-2175
    Poč.str.4 s.
    Forma vydáníTištěná - P
    AkceWORLD CONFERENCE ON TITANIUM /12./
    Datum konání19.06.2011 - 24.06.2011
    Místo konáníBeijing
    ZeměCN - Čína
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CN - Čína
    Klíč. slovaTi-6A1-4V ; electric discharge machining (EDM) ; scanning electron microscopy ; cell growth
    Vědní obor RIVEI - Biotechnologie a bionika
    CEPTA01011141 GA TA ČR - Technologická agentura ČR
    Institucionální podporaFGU-C - RVO:67985823
    UT WOS000398128800109
    AnotaceElectric discharge machining (EDM) with relatively high peak currents was performed on Ti-6A1-4V alloy. Several experimental inverstigations have been undertaken in order to assess whether EDM process is viable surface treatment technique for application in orthopaedics. The surface roughness, chemical alterations of surface and osteointegration in vitro have been studied. EDM process created carbon enriched surface layer and sufficient surface roughness for improved osteointegration. Tensile properties are not substantially varied by EDM, however EDM has detrimental effect on fatigue endurance. Poor fatigue performance of material after EDM process irrespective of its original microstructure can be attributed to surface microcracks, brittle oxidized surface recast layer, internal tensile stresses and notch sensitivity of titanium alloys. These detrimental effects can be partly avoided by subsequent heat treatments. Microstructural changes of surface and subsurface layers have been observed by means of scanning electron microscopy. Fatigue performance is found to be the main limit for potential application of EDM process in orthopedics.
    PracovištěFyziologický ústav
    KontaktLucie Trajhanová, lucie.trajhanova@fgu.cas.cz, Tel.: 241 062 400
    Rok sběru2018