The Application of Miniaturized Three-Point-Bend Specimens for Determination of the Reference Temperature of A533 Cl.1 Steel

  1. 1.
    SYSNO ASEP0481466
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevThe Application of Miniaturized Three-Point-Bend Specimens for Determination of the Reference Temperature of A533 Cl.1 Steel
    Tvůrce(i) Stratil, Luděk (UFM-A) ORCID
    Šiška, Filip (UFM-A) RID, ORCID
    Dlouhý, Ivo (UFM-A) RID, ORCID
    Serrano, M. (ES)
    Celkový počet autorů4
    Číslo článku041410
    Zdroj.dok.Journal of Pressure Vessel Technology-Transactions of the Asme - ISSN 0094-9930
    Roč. 139, č. 4 (2017)
    Poč.str.6 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovafracture toughness ; Master Curve ; the reference temperature ; JRQ steel ; miniaturized specimens
    Vědní obor RIVJL - Únava materiálu a lomová mechanika
    Obor OECDAudio engineering, reliability analysis
    CEPGJ15-21292Y GA ČR - Grantová agentura ČR
    ED1.1.00/02.0068 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUFM-A - RVO:68081723
    UT WOS000403902100022
    EID SCOPUS85019699188
    DOI10.1115/1.4036532
    AnotaceThis contribution deals with the determination of the reference temperature of JRQ steel using miniaturized
    specimens. The dimensions of the miniaturized specimens used were 3 × 4 × 27 mm (thickness × width ×
    length). This specimen type allows utilizing a limited amount of test material or the broken halves of pre-cracked
    Charpy or larger specimens. The test material comes from the broken halves of 0.5T SE(B) specimens
    previously tested for the determination of the reference temperature at Ciemat, Madrid. The fracture toughness
    tests were performed in the transition region of the steel according to the recommendations of the standard
    ASTM E1921 and according to Wallin’s recommended temperature range of miniaturized specimens. The
    reference temperature of the Master Curve was very similar to the ones obtained from three-point-bend
    specimens of sizes 0.2T, 0.4T and 0.5T. The results obtained confirm a necessity to conduct tests at low
    temperatures and to test a sufficient number of specimens in order to generate enough valid data for the
    determination of the reference temperature.