Feasibility study of fast swept divertor strike point suppressing transient heat fluxes in big tokamaks.

  1. 1.
    SYSNO ASEP0481373
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevFeasibility study of fast swept divertor strike point suppressing transient heat fluxes in big tokamaks.
    Tvůrce(i) Horáček, Jan (UFP-V) RID, ORCID
    Cunningham, G. (GB)
    Entler, Slavomír (UFP-V) ORCID
    Dobias, P. (FR)
    Duban, R. (CZ)
    Imríšek, Martin (UFP-V) RID
    Markovič, Tomáš (UFP-V) RID
    Havlíček, Josef (UFP-V) RID, ORCID
    Enikeev, R. (RU)
    Zdroj.dok.Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
    Roč. 123, November (2017), s. 646-649
    Poč.str.4 s.
    Forma vydáníTištěná - P
    AkceSOFT 2016: Symposium on Fusion Technology /29./
    Datum konání05.09.2016 - 09.09.2016
    Místo konáníPrague
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaDEMO ; ELM ; Divertor ; Heat flux ; Tokamak
    Vědní obor RIVJF - Jaderná energetika
    Obor OECDNuclear related engineering
    CEPGA16-14228S GA ČR - Grantová agentura ČR
    LM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LG14002 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000418992000134
    EID SCOPUS85011103413
    DOI10.1016/j.fusengdes.2017.01.027
    Anotacen order to avoid metal surface melting of divertor targets of big tokamak fusion reactors by localized ELM heat loads, sudden detachment loss or VDEs, we study a new technique of spreading the heat flux by harmonic divertor strike point sweeping using a dedicated divertor coil. We ran 2D dynamic heat conduction simulation using real infra-red data of large ELMs heat fluxes on JET divertor target, rescaled for EU DEMO reactor (B-0 = 6 T, I-p =21 MA, R-0 = 9 m). Aiming for the surface temperature suppression factor of 4, this requires sweeping with amplitude*frequency=7cm*2 kHz. Building the divertor coil out of 27 tons of copper, this requires 0.8 MW cooling. Triggered by analog divertor heat flux signal, dedicated dynamic Fiesta simulation scenario requires 54 capacitive energy storages at 1500 V (6mF) discharged into 54 divertor coils, each with AC current of 130kA for each ELM event for similar to 4 ms (with waiting time 40 ms). The Ix B-tor forces would yield less than 0.1 mm rotational vibrations of the coil at the ELM frequency (similar to 20 Hz). The DEMO divertor surface temperature suppression reaches factor of 9 with 18 kV, 20 cm, 7.5 kHz, 400 kA. We also calculate system requirements (0.6mF, 5 kV & 60kA -> suppression factor = 2) for ASDEX Upgrade using the upper divertor coil. Since we found no show-stoppers, this technique seems attractive for big tokamaks.