Počet záznamů: 1  

Surface Tension of Supercooled Water: Inflection Point-Free Course down to 250 K Confirmed Using a Horizontal Capillary Tube

  1. 1.
    SYSNO ASEP0481327
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSurface Tension of Supercooled Water: Inflection Point-Free Course down to 250 K Confirmed Using a Horizontal Capillary Tube
    Tvůrce(i) Vinš, Václav (UT-L) RID, ORCID
    Hošek, Jan (UT-L) RID
    Hykl, Jiří (UT-L) RID, ORCID
    Hrubý, Jan (UT-L) RID, ORCID
    Celkový počet autorů4
    Zdroj.dok.Journal of Chemical and Engineering Data. - : American Chemical Society - ISSN 0021-9568
    Roč. 62, č. 11 (2017), s. 3823-3832
    Poč.str.10 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovahorizontal technique ; metastable liquid ; supercooled
    Vědní obor RIVBJ - Termodynamika
    Obor OECDThermodynamics
    CEPGJ15-07129Y GA ČR - Grantová agentura ČR
    Institucionální podporaUT-L - RVO:61388998
    UT WOS000415140900020
    EID SCOPUS85033594551
    DOI10.1021/acs.jced.7b00519
    AnotaceThe temperature course of the surface tension of supercooled water was suspected to exhibit an anomalous feature – the so called second inflection point (SIP). Besides some theoretical and molecular simulation studies, this hypothesis was primarily supported by experimental data by P.T. Hacker (1951). Recently, the present group performed accurate surface tension measurements down to –26 °C using a modified capillary rise technique which, in contrast to Hacker’s data, showed no SIP anomaly. In order to confirm that the qualitatively different observations are not related to some fundamental phenomenon, we developed an experimental device employing basically the same method as Hacker with a horizontal capillary tube. New experimental data for the surface tension of supercooled water measured with the horizontal capillary setup down to –23 °C are presented in this study. The new data show a very good agreement with the previous capillary rise measurements. It was confirmed that the temperature dependence of the surface tension is free of SIP in a temperature range from –23 °C to 23 °C and can be well represented by the IAPWS standard extrapolated below 0.01 °C. However, a small systematic deviation from the IAPWS correlation can be seen at temperatures below –15 °C.
    PracovištěÚstav termomechaniky
    KontaktMarie Kajprová, kajprova@it.cas.cz, Tel.: 266 053 154 ; Jana Lahovská, jaja@it.cas.cz, Tel.: 266 053 823
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.