Počet záznamů: 1  

Polymer brush-functionalized chitosan hydrogels as antifouling implant coatings

  1. 1.
    SYSNO ASEP0475191
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevPolymer brush-functionalized chitosan hydrogels as antifouling implant coatings
    Tvůrce(i) Buzzacchera, I. (NL)
    Vorobii, M. (DE)
    Kostina, N. Yu. (DE)
    de los Santos Pereira, Andres (UMCH-V) RID, ORCID
    Riedel, Tomáš (UMCH-V) RID, ORCID
    Bruns, M. (DE)
    Ogieglo, W. (DE)
    Möller, M. (DE)
    Wilson, C. J. (NL)
    Rodriguez-Emmenegger, C. (DE)
    Zdroj.dok.Biomacromolecules. - : American Chemical Society - ISSN 1525-7797
    Roč. 18, č. 6 (2017), s. 1983-1992
    Poč.str.10 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovachitosan ; hemocompatible ; polymer brushes
    Vědní obor RIVCE - Biochemie
    Obor OECDBiochemistry and molecular biology
    CEPGBP205/12/G118 GA ČR - Grantová agentura ČR
    Institucionální podporaUMCH-V - RVO:61389013
    UT WOS000403387100031
    EID SCOPUS85020692084
    DOI10.1021/acs.biomac.7b00516
    AnotaceImplantable sensor devices require coatings that efficiently interface with the tissue environment to mediate biochemical analysis. In this regard, bioinspired polymer hydrogels offer an attractive and abundant source of coating materials. However, upon implantation these materials generally elicit inflammation and the foreign body reaction as a consequence of protein fouling on their surface and concomitant poor hemocompatibility. In this report we investigate a strategy to endow chitosan hydrogel coatings with antifouling properties by the grafting of polymer brushes in a “grafting-from” approach. Chitosan coatings were functionalized with polymer brushes of oligo(ethylene glycol) methyl ether methacrylate and 2-hydroxyethyl methacrylate using photoinduced single electron transfer living radical polymerization and the surfaces were thoroughly characterized by XPS, AFM, water contact angle goniometry, and in situ ellipsometry. The antifouling properties of these new bioinspired hydrogel-brush coatings were investigated by surface plasmon resonance. The influence of the modifications to the chitosan on hemocompatibility was assessed by contacting the surfaces with platelets and leukocytes. The coatings were hydrophilic and reached a thickness of up to 180 nm within 30 min of polymerization. The functionalization of the surface with polymer brushes significantly reduced the protein fouling and eliminated platelet activation and leukocyte adhesion. This methodology offers a facile route to functionalizing implantable sensor systems with antifouling coatings that improve hemocompatibility and pave the way for enhanced device integration in tissue.
    PracovištěÚstav makromolekulární chemie
    KontaktEva Čechová, cechova@imc.cas.cz ; Tel.: 296 809 358
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.