Počet záznamů: 1  

Determination of vanadium in titanate-based ferroelectrics by INAA with discriminating gamma-ray spectrometry

  1. 1.
    SYSNO ASEP0474041
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevDetermination of vanadium in titanate-based ferroelectrics by INAA with discriminating gamma-ray spectrometry
    Tvůrce(i) Kameník, Jan (UJF-V) RID, ORCID, SAI
    Dragounová, K. (CZ)
    Kučera, Jan (UJF-V) RID, ORCID, SAI
    Bryknar, Z. (CZ)
    Trepakov, Vladimír (FZU-D) RID
    Strunga, Vladimír (UJF-V) ORCID, SAI
    Celkový počet autorů6
    Zdroj.dok.Journal of Radioanalytical and Nuclear Chemistry. - : Springer - ISSN 0236-5731
    Roč. 311, č. 2 (2017), s. 1333-1338
    Poč.str.6 s.
    Forma vydáníTištěná - P
    Akce1st International Conference on Radioanalytical and Nuclear chemistry (RANC)
    Datum konání10.04.2016 - 15.04.2016
    Místo konáníBudapest
    ZeměHU - Maďarsko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaTitanate-based ferroelectrics ; Vanadium ; INAA ; discriminating gamma-ray spectrometry
    Vědní obor RIVCB - Analytická chemie, separace
    Obor OECDAnalytical chemistry
    Vědní obor RIV – spolupráceFyzikální ústav - Fyzika pevných látek a magnetismus
    CEPGBP108/12/G108 GA ČR - Grantová agentura ČR
    LM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaFZU-D - RVO:68378271 ; UJF-V - RVO:61389005
    UT WOS000394343200046
    EID SCOPUS84994745740
    DOI10.1007/s10967-016-5101-1
    AnotaceInstrumental neutron activation analysis was used for determination of vanadium mass fraction in crystals of incipient ferroelectric strontium titanate and ferroelectric barium titanate. In order to improve vanadium limit of detection, discriminating gamma-ray spectrometry was used by inserting an absorption filter between the samples and an HPGe detector. The use of the absorption lead filter 6-mm thick yielded improvement of the vanadium limit of detection by a factor of two. The vanadium mass fraction determined in a quality control sample, which was NIST standard reference material SRM 1648 Urban Particulate Matter, was in close agreement with the certified value.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2018
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.