Počet záznamů: 1  

First high-statistics and high-resolution recoil-ion data from the WITCH retardation spectrometer

  1. 1.
    SYSNO ASEP0471144
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevFirst high-statistics and high-resolution recoil-ion data from the WITCH retardation spectrometer
    Tvůrce(i) Finlay, P. (BE)
    Breitenfeldt, M. (BE)
    Porobic, T. (BE)
    Wursten, E. (BE)
    Ban, G. (FR)
    Beck, M. (DE)
    Couratin, C. (FR)
    Fabian, X. (FR)
    Flechard, X. (FR)
    Friedag, P. (DE)
    Gluck, F. (DE)
    Herlert, A. (CH)
    Knecht, A. (BE)
    Kozlov, V. Y. (BE)
    Lienard, E. (FR)
    Soti, G. (BE)
    Tandecki, M. (BE)
    Traykov, E. (BE)
    Van Gorp, S. (BE)
    Weinheimer, C. (DE)
    Zákoucký, Dalibor (UJF-V) RID, SAI, ORCID
    Severijns, N. (BE)
    Celkový počet autorů22
    Číslo článku206
    Zdroj.dok.European Physical Journal A. - : Springer - ISSN 1434-6001
    Roč. 52, č. 7 (2016)
    Poč.str.16 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovabeta-decay ; multichannel plate detector
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    CEPLG13031 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LG15052 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000391616700001
    EID SCOPUS84980016023
    DOI10.1140/epja/i2016-16206-y
    AnotaceThe first high-statistics and high-resolution data set for the integrated recoil-ion energy spectrum following the beta(+) decay of Ar-35 has been collected with the WITCH retardation spectrometer located at CERN-ISOLDE. Over 25 million recoil-ion events were recorded on a large-area multichannel plate (MCP) detector with a time-stamp precision of 2 ns and position resolution of 0.1 mm due to the newly upgraded data acquisition based on the LPC Caen FASTER protocol. The number of recoil ions was measured for more than 15 different settings of the retardation potential, complemented by dedicated background and half-life measurements. Previously unidentified systematic effects, including an energy-dependent efficiency of the main MCP and a radiation-induced time-dependent background, have been identified and incorporated into the analysis. However, further understanding and treatment of the radiation-induced background requires additional dedicated measurements and remains the current limiting factor in extracting a beta-neutrino angular correlation coefficient for Ar-35 decay using the WITCH spectrometer.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2017
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.