Počet záznamů: 1  

Commissioning of the vacuum system of the KATRIN Main Spectrometer

  1. 1.
    SYSNO ASEP0460113
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCommissioning of the vacuum system of the KATRIN Main Spectrometer
    Tvůrce(i) Arenz, M. (DE)
    Dragoun, Otokar (UJF-V) RID, SAI
    Kovalík, Alojz (UJF-V) RID, ORCID, SAI
    Lebeda, Ondřej (UJF-V) RID, ORCID, SAI
    Ryšavý, Miloš (UJF-V) RID, ORCID, SAI
    Sentkerestiová, Jana (UJF-V) SAI
    Slezák, Martin (UJF-V) RID, ORCID
    Špalek, Antonín (UJF-V) RID
    Vénos, Drahoslav (UJF-V) RID, SAI, ORCID
    Zbořil, Miroslav (UJF-V) ORCID
    Celkový počet autorů150
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 11, APR (2016), P04011
    Poč.str.36 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovagas systems and purification ; neutriono detectors ; spectrometers
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    CEPGAP203/12/1896 GA ČR - Grantová agentura ČR
    LG14004 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000375746400030
    DOI10.1088/1748-0221/11/04/P04011
    AnotaceThe KATRIN experiment will probe the neutrino mass by measuring the beta-electron energy spectrum near the endpoint of tritium beta-decay. An integral energy analysis will be performed by an electro-static spectrometer ("Main Spectrometer"), an ultra-high vacuum vessel with a length of 23.2 m, a volume of 1240 m(3), and a complex inner electrode system with about 120 000 individual parts. The strong magnetic field that guides the beta-electrons is provided by super-conducting solenoids at both ends of the spectrometer. Its influence on turbo-molecular pumps and vacuum gauges had to be considered. A system consisting of 6 turbo-molecular pumps and 3 km of non-evaporable getter strips has been deployed and was tested during the commissioning of the spectrometer. In this paper the configuration, the commissioning with bake-out at 300 degrees C, and the performance of this system are presented in detail. The vacuum system has to maintain a pressure in the 10(-11) mbar range. It is demonstrated that the performance of the system is already close to these stringent functional requirements for the KATRIN experiment, which will start at the end of 2016.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2017
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.