Počet záznamů: 1  

Biological evaluation of ultra-fine titanium with improved mechanical strength for dental implant engineering

  1. 1.
    SYSNO ASEP0456259
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevBiological evaluation of ultra-fine titanium with improved mechanical strength for dental implant engineering
    Tvůrce(i) Ostrovská, L. (CZ)
    Vištejnová, L. (CZ)
    Dzugan, J. (CZ)
    Slama, P. (CZ)
    Kubina, T. (CZ)
    Ukraintsev, Egor (FZU-D) RID, ORCID
    Kubies, Dana (UMCH-V) RID, ORCID
    Králíčková, M. (CZ)
    Hubálek Kalbáčová, M. (CZ)
    Zdroj.dok.Journal of Materials Science. - : Springer - ISSN 0022-2461
    Roč. 51, č. 6 (2016), s. 3097-3110
    Poč.str.14 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovamesenchymal stem-cells ; thermal-stability
    Vědní obor RIVBO - Biofyzika
    Vědní obor RIV – spolupráceÚstav makromolekulární chemie - Makromolekulární chemie
    CEPED1.1.00/02.0109 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    NT13297 GA MZd - Ministerstvo zdravotnictví
    Institucionální podporaFZU-D - RVO:68378271 ; UMCH-V - RVO:61389013
    UT WOS000367681300030
    EID SCOPUS84953367658
    DOI10.1007/s10853-015-9619-3
    AnotaceTitanium, the gold standard for dental implant materials, is distinguished by its exceptional biocompatibility; however, from a long-term perspective, titanium still lacks sufficient loading strength. Commercially pure titanium with grain size 30 mu m was processed by equal channel angular pressing, and two novel mechanically improved types of titanium material with grain size 4.6 and a parts per thousand currency sign1 A mu m were obtained. The surfaces of these ultra-fine grained titanium samples were further mechanically treated by grinding and polishing, and their surfaces were characterized by atomic force microscopy and contact angle measurement. Osteoblast-like cells and human mesenchymal stem cells were used to evaluate the cytocompatibility of these titanium samples. The cell metabolic activity, cell number, cell area, morphology, and cell adhesion quality during the early stage (2 h) and prolonged cultivation (48 h) were determined.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2016
Počet záznamů: 1  