Počet záznamů: 1  

Power loads to misaligned edges in COMPASS

  1. 1.
    SYSNO ASEP0451082
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVZáznam nebyl označen do RIV
    NázevPower loads to misaligned edges in COMPASS
    Tvůrce(i) Dejarnac, Renaud (UFP-V) RID, ORCID
    Corre, C. (FR)
    Vondráček, Petr (UFP-V) RID, ORCID
    Gardarein, J.-L. (FR)
    Gauthier, E. (FR)
    Gunn, J. P. (FR)
    Horáček, Jan (UFP-V) RID, ORCID
    Hron, Martin (UFP-V) RID, ORCID
    Komm, Michael (UFP-V) RID, ORCID
    Pánek, Radomír (UFP-V) RID
    Pitts, R. A. (GB)
    Zdroj.dok.15th International Conference on PLASMA-FACING MATERIALS and COMPONENTS for FUSION APPLICATIONS. - Aix-en-Provence : Commissariat à l'Energie Atomique, 2015
    Forma vydáníOnline - E
    AkceInternational Conference on PLASMA-FACING MATERIALS and COMPONENTS for FUSION APPLICATIONS/15./
    Datum konání18.05.2015-22.05.2015
    Místo konáníAix-en-Provence
    ZeměFR - Francie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.FR - Francie
    Klíč. slovaHeat loads ; limiter ; leading edge ; IR thermography
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Institucionální podporaUFP-V - RVO:61389021
    AnotaceA major issue for ITER divertor are leading edges (LE) between monoblocks. Geometrical arguments assume that power loads on the top and side of a LE may be described by Qn = q//,0*sin(α) and Qs = q//,0*cos(α), respectively. This assumption has recently been challenged by edge melting experiments on JET, which found that the theoretically expected Qs needed to be reduced by a factor 5 (fs = 0.2) in L-mode to explain the observed power load, whilst Qn was as expected (fn = 1), violating power balance. A dedicated experiment has thus been designed on COMPASS to study this phenomenon. Simulations of this experiment show mitigation factors (0.5 < fs < 0.8) increasing with LE misalignment and find that missing power to the side is re-deposited on the next tile top surface, yielding fn > 1 consistent with power balance. Using simulated power load profiles input to 2D thermal calculations agree well with IR data. Importantly, low values of fs reported in JET case are not observed in COMPASS
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2016