Počet záznamů: 1
Decontamination of Oils Contaminated with Polychlorinated Biphenyls and Dibenzyl Disulfide Using Polar Aprotic Solvents
- 1.
SYSNO ASEP 0445923 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Ostatní články Název Decontamination of Oils Contaminated with Polychlorinated Biphenyls and Dibenzyl Disulfide Using Polar Aprotic Solvents Tvůrce(i) Kaštánek, František (UCHP-M) RID, SAI, ORCID
Matějková, Martina (UCHP-M) RID, ORCID, SAI
Spáčilová, Lucie (UCHP-M) RID, SAI
Maléterová, Ywetta (UCHP-M) RID, ORCID, SAI
Kaštánek, P. (CZ)
Šolcová, Olga (UCHP-M) RID, ORCID, SAIZdroj.dok. International Journal of Engineering Science and Innovative Technology. ON -LINE - ISSN 2319-5967
Roč. 4, č. 2 (2015), s. 41-48Poč.str. 8 s. Forma vydání Online - E Jazyk dok. eng - angličtina Země vyd. IN - Indie Klíč. slova corrosive sulfur ; dibenzyl disulfide ; polar aprotic solvents Vědní obor RIV CI - Průmyslová chemie a chemické inženýrství CEP TA04020151 GA TA ČR - Technologická agentura ČR Institucionální podpora UCHP-M - RVO:67985858 Anotace The highest efficiency, around 70 % in single-step extraction exhibited NMP. NMP was evaluated as having the best chance to be used in industry. It was shown that for some transformer oils the separation of corrosive sulfur with the common technique of filtration through a layer of commercially available sorbent (for example Fuller’s earth) is totally inadequate. However, extraction efficiency of DBDS from contaminated transformer oil with the help of NMP is sufficiently high over 99 % and feasible in a fair time of about 20 minutes. The remaining concentration of DBDS after single-step extraction from transformer oil containing up to100 ppm DBDS was low enough (approx. 0.1 ppm or non-detectable). Detection of corrosive sulfur in transformer oil after extraction with NMP has been also performed by Siemens test method (IEC 62535) and by updated ASTM 1275B proposed by CIGRE Covered Conductor Deposition test method and was negative. It is possible to consider the transformer oil after the extraction procedure as corrosive sulfur free. Traces of solvent in the oil after extraction were quantitatively separated from treated oil by purification via simple liquid-solid extraction with commercial Si-Al-Mg based inorganic sorbent containing attapulgite. Pracoviště Ústav chemických procesů Kontakt Eva Jirsová, jirsova@icpf.cas.cz, Tel.: 220 390 227 Rok sběru 2016 Elektronická adresa http://www.ijesit.com/Volume%204/Issue%202/IJESIT201502_06.pdf
Počet záznamů: 1