Počet záznamů: 1
Tensile stress analyses of the hip joint endoprosthesis ceramic head with real shape deviations
- 1.
SYSNO ASEP 0441584 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Tensile stress analyses of the hip joint endoprosthesis ceramic head with real shape deviations Tvůrce(i) Fuis, Vladimír (UT-L) RID, ORCID Celkový počet autorů 1 Zdroj.dok. 5th International Conference on Biomedical Engineering in Vietnam. - NEW YORK : Springer Verlag, 2015 - ISSN 1680-0737 - ISBN 978-3-319-11775-1 Rozsah stran s. 450-453 Poč.str. 4 s. Forma vydání Nosič - C Akce International Conference on the Development of Biomedical Engineering /5./ Datum konání 16.06.2014-18.06.2014 Místo konání Ho Chi Minh City Země VN - Vietnam Typ akce WRD Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova total hip joint endoprosthesis ; ceramics head ; micro and macro shape deviations Vědní obor RIV JH - Keramika, žáruvzdorné materiály a skla CEP GA13-34632S GA ČR - Grantová agentura ČR Institucionální podpora UT-L - RVO:61388998 UT WOS 000357778100111 EID SCOPUS 84928257085 DOI 10.1007/978-3-319-11776-8_111 Anotace In vivo fracture of ceramic heads of total hip joint endoprostheses has been stated in a not negligible number of patients in the Czech Republic hospitals, some time ago. The reliability of the ceramic head is based on the Weibull weakest link theory. The probability of the failure depends on the tensile stress values in the head, on the volume in which stress acts and on the material parameters of the used bioceramics. The stress analyses of the ceramic heads were realized using computational modelling-FEM system ANSYS under ISO 7206-5 loading. The maximum values of the tensile stress in the ceramic head are significantly influenced on the shape deviations of conical surfaces of the head and the stem cones. There are two types of the shape deviations–the first is macro deviations (different angle of the taper of the stem cone and the head cone), the second is micro shape deviations (the stochastic distribution of unevenness of cone contact surfaces in order micrometers). The macro and micro shape deviations of the real cones were carried out using the IMS-UMPIRE measuring equipment. By computational modelling it has been proved that the character and the size of shape deviations on a conical contact area between the stem and the head of hip joint endoprosthesis have a pronounced influence on the character and the value of stress in the head and, hence, on the probability of the head's failure. Ignorance of this influence can lead to unforeseen failures of ceramic heads and thus to cast doubt on the trustworthiness of a certain type of total hip joint endoprosthesis and of surgical treatment. Pracoviště Ústav termomechaniky Kontakt Marie Kajprová, kajprova@it.cas.cz, Tel.: 266 053 154 ; Jana Lahovská, jaja@it.cas.cz, Tel.: 266 053 823 Rok sběru 2017
Počet záznamů: 1