Počet záznamů: 1  

Tensile stress analyses of the hip joint endoprosthesis ceramic head with real shape deviations

  1. 1.
    SYSNO ASEP0441584
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevTensile stress analyses of the hip joint endoprosthesis ceramic head with real shape deviations
    Tvůrce(i) Fuis, Vladimír (UT-L) RID, ORCID
    Celkový počet autorů1
    Zdroj.dok.5th International Conference on Biomedical Engineering in Vietnam. - NEW YORK : Springer Verlag, 2015 - ISSN 1680-0737 - ISBN 978-3-319-11775-1
    Rozsah strans. 450-453
    Poč.str.4 s.
    Forma vydáníNosič - C
    AkceInternational Conference on the Development of Biomedical Engineering /5./
    Datum konání16.06.2014-18.06.2014
    Místo konáníHo Chi Minh City
    ZeměVN - Vietnam
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovatotal hip joint endoprosthesis ; ceramics head ; micro and macro shape deviations
    Vědní obor RIVJH - Keramika, žáruvzdorné materiály a skla
    CEPGA13-34632S GA ČR - Grantová agentura ČR
    Institucionální podporaUT-L - RVO:61388998
    UT WOS000357778100111
    EID SCOPUS84928257085
    DOI10.1007/978-3-319-11776-8_111
    AnotaceIn vivo fracture of ceramic heads of total hip joint endoprostheses has been stated in a not negligible number of patients in the Czech Republic hospitals, some time ago. The reliability of the ceramic head is based on the Weibull weakest link theory. The probability of the failure depends on the tensile stress values in the head, on the volume in which stress acts and on the material parameters of the used bioceramics. The stress analyses of the ceramic heads were realized using computational modelling-FEM system ANSYS under ISO 7206-5 loading. The maximum values of the tensile stress in the ceramic head are significantly influenced on the shape deviations of conical surfaces of the head and the stem cones. There are two types of the shape deviations–the first is macro deviations (different angle of the taper of the stem cone and the head cone), the second is micro shape deviations (the stochastic distribution of unevenness of cone contact surfaces in order micrometers). The macro and micro shape deviations of the real cones were carried out using the IMS-UMPIRE measuring equipment. By computational modelling it has been proved that the character and the size of shape deviations on a conical contact area between the stem and the head of hip joint endoprosthesis have a pronounced influence on the character and the value of stress in the head and, hence, on the probability of the head's failure. Ignorance of this influence can lead to unforeseen failures of ceramic heads and thus to cast doubt on the trustworthiness of a certain type of total hip joint endoprosthesis and of surgical treatment.