Počet záznamů: 1  

Optical Frequency References for Laser Interferometry

  1. 1.
    SYSNO ASEP0441272
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevOptical Frequency References for Laser Interferometry
    Tvůrce(i) Hrabina, Jan (UPT-D) RID, ORCID, SAI
    Šarbort, Martin (UPT-D) RID, ORCID, SAI
    Acef, O. (FR)
    Du Burck, F. (FR)
    Chiodo, N. (FR)
    Číp, Ondřej (UPT-D) RID, SAI, ORCID
    Lazar, Josef (UPT-D) RID, ORCID, SAI
    Celkový počet autorů7
    Zdroj.dok.Optics and Measurement Conference 2014 (Proceedings of SPIE 9442). - Bellingham : SPIE, 2014 - ISSN 0277-786X - ISBN 9781628415575
    Rozsah stran94420f: 1-6
    Poč.str.6 s.
    Forma vydáníOnline - E
    AkceOptics and Measurement Conference 2014 (OaM 2014)
    Datum konání07.10.2014-10.10.2014
    Místo konáníLiberec
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovalaser standards ; iodine absorption cells ; spectroscopy ; laser frequency stabilization
    Vědní obor RIVBH - Optika, masery a lasery
    CEPGB14-36681G GA ČR - Grantová agentura ČR
    TA02010711 GA TA ČR - Technologická agentura ČR
    TA01010995 GA TA ČR - Technologická agentura ČR
    TE01020233 GA TA ČR - Technologická agentura ČR
    LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    7AMB14FR040 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000349403500014
    EID SCOPUS84922824813
    DOI10.1117/12.2086262
    AnotaceOptical frequency references for laser standards based on molecular iodine absorption cells represent one of the most used tool for frequency stabilization of lasers operating in a visible spectral range. In the industry oriented laser measurements and similar laser interferometry applications performed at atmospheric conditions, a refractive index of air plays a role of main uncertainty contributor. In these cases there is no need to use technologically complicated and expensive iodine references made of pure fused silica with precise pressure control of absorpbing media. A set of iodine cells made of borosilicate glass was filled with certain amount of absorbing media to define the saturation point of iodine inside. A combination of these two approaches (pyrex material and controlled saturation pressure of iodine) allows us to simplify the laser stabilization setup (there is no need of additional iodine pressure level control) and reduce the overall reference’s costs with ensuring of sufficient frequency stability of the system at the same time. Spectral properties of manufactured cells were tested by hyperfine transitions linewidth measurement and comparison with results from traditional fused silica cells was done to investigate the long-term iodine purity inside the references. As the transitions linewidth method shows a very high sensitivity to iodine purity level, this method is proposed to be an alternative approach in investigation of contamination in iodine absorption cells where traditionally used techniques - laser induced fluorescence (LIF) and absolute frequency shifts measurement - can not be used.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2016
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.