Utilisation of radiological methods for investigation of trabecular bone deformation behaviour

  1. 1.
    SYSNO ASEP0430894
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVZáznam nebyl označen do RIV
    NázevUtilisation of radiological methods for investigation of trabecular bone deformation behaviour
    Tvůrce(i) Kytýř, D. (CZ)
    Doktor, T. (CZ)
    Fíla, Tomáš (UTAM-F) RID, SAI, ORCID
    Koudelka_ml., Petr (UTAM-F) RID, SAI, ORCID
    Zlámal, Petr (UTAM-F) RID, SAI, ORCID
    Jiroušek, Ondřej (UTAM-F) RID, SAI
    Kumpová, Ivana (UTAM-F) RID, SAI, ORCID
    Celkový počet autorů7
    Zdroj.dok.Experimental methods and numerical simulation in engineering science. Proceedings of the XIVth bilateral Czech/German symposium. - Wuppertal : Institute for statics and dynamics of structures. University of Wuppertal, 2014 / Harte R. - ISBN N
    Rozsah strans. 66-69
    Poč.str.4 s.
    Forma vydáníTištěná - P
    AkceExperimental methods and numerical simulation in engineering science. Bilateral Czech/German symposium. /14./
    Datum konání04.06.2014-07.06.2014
    Místo konáníWuppertal
    ZeměDE - Německo
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovacomputed micro-tomography ; trabecular bone ; micro-mechanical testing
    Vědní obor RIVJJ - Ostatní materiály
    CEPED1.1.00/02.0060 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUTAM-F - RVO:68378297
    AnotaceDeeper understanding of the relationship between morphology, micro- mechanical properties at the bone tissue level and overall mechanical properties of the bone is important for assessment of bone physiological and pathological behaviour. Modern radiological methods (e.g. computed micro-tomography) are powerful instruments for investigation of the internal structure. Using the time lapse tomography enabled assessment of deformation response to the applied loading and monitoring of damage propagation. Different custom based set-ups of high resolution micro-focus X-ray computed tomography equipped with scintillator or single-photon counting detector were used for imaging at both meso and micro levels.