Quantification of structural changes of UHMWPE components in total joint replacements

  1. 1.
    SYSNO ASEP0427703
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevQuantification of structural changes of UHMWPE components in total joint replacements
    Tvůrce(i) Fulín, P. (CZ)
    Pokorný, D. (CZ)
    Šlouf, Miroslav (UMCH-V) RID, ORCID
    Nevoralová, Martina (UMCH-V) RID, ORCID
    Vacková, Taťana (UMCH-V) RID
    Dybal, Jiří (UMCH-V) RID, ORCID
    Pilař, Jan (UMCH-V) RID, ORCID
    Zdroj.dok.BMC Musculoskeletal Disorders
    Roč. 15, 28 March (2014), 109_1-109_8
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaUHMWPE ; oxidative damage ; residual radicals
    Vědní obor RIVFI - Traumatologie, ortopedie
    CEPTA01011406 GA TA ČR - Technologická agentura ČR
    NT12229 GA MZd - Ministerstvo zdravotnictví
    Institucionální podporaUMCH-V - RVO:61389013
    UT WOS000335183900002
    EID SCOPUS84898426501
    DOI10.1186/1471-2474-15-109
    AnotaceAt present time the number of implantations of joint replacements as well as their revisions increases. Higher demands are required on the quality and longevity of implants. The aim of this work was to determine the degree of oxidative degradation and the amount of free/residual radicals in selected ultra-high molecular weight polyethylene (UHMWPE) components of the joint replacements and demonstrate that the measured values are closely connected with quality and lifetime of the polymer components. We tested both new (4 samples) and explanted (4 samples) UHMWPE polymers for total joint replacements. The samples were characterized by infrared spectroscopy (IR), electron spin resonance (ESR) and microhardness (MH) test. The IR measurements yielded the values of oxidation index and trans-vinylene index. The ESR measurements gave the free radicals concentration. In the group of new polyethylene components, we found oxidation index values ranging from 0.00-0.03 to 0.24. The trans-vinylene index values ranged from 0.044 to 0.080. The value of free radical concentration was zero in virgin and also in sample of Beznoska Company and non-zero in the other samples. In the group of explanted components, the measured values were associated with their history, micromechanical properties and performance in vivo. We demonstrated that measuring of oxidative damage may help the orthopaedic surgeon in estimating the quality of UHMWPE replacement component and thus radically to avoid early joint replacement failure due to worse polyethylene quality.