Počet záznamů: 1
Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory
- 1.
SYSNO ASEP 0399800 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Techniques for measuring aerosol attenuation using the Central Laser Facility at the Pierre Auger Observatory Tvůrce(i) Abreu, P. (PT)
Aglietta, M. (IT)
Ahlers, M. (US)
Boháčová, Martina (FZU-D) RID, ORCID
Chudoba, Jiří (FZU-D) RID, ORCID
Ebr, Jan (FZU-D) RID, ORCID
Mandát, Dušan (FZU-D) RID, ORCID
Nečesal, Petr (FZU-D)
Nožka, Libor (FZU-D) RID, ORCID
Palatka, Miroslav (FZU-D) RID, ORCID, SAI
Pech, Miroslav (FZU-D) RID, ORCID
Prouza, Michael (FZU-D) RID, ORCID
Řídký, Jan (FZU-D) RID, ORCID
Schovancová, Jaroslava (FZU-D)
Schovánek, Petr (FZU-D) RID, ORCID
Tománková, L. (CZ)
Trávníček, Petr (FZU-D) RID, ORCID
Vícha, Jakub (FZU-D) RID, ORCIDCelkový počet autorů 506 Zdroj.dok. Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
Roč. 8, APR (2013), s. 1-29Poč.str. 29 s. Jazyk dok. eng - angličtina Země vyd. GB - Velká Británie Klíč. slova data analysis ; large detector systems for particle and astroparticle physics ; detector alignment and calibration methods (lasers, sources) Vědní obor RIV BF - Elementární částice a fyzika vys. energií CEP MEB111003 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy KJB100100904 GA AV ČR - Akademie věd LA08016 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LC527 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy 1M06002 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy CEZ AV0Z10100502 - FZU-D (2005-2011) AV0Z10100522 - FZU-D (2005-2011) UT WOS 000317462400016 DOI 10.1088/1748-0221/8/04/P04009 Anotace The Pierre Auger Observatory in Malargue, Argentina, is designed to study the properties of ultra-high energy cosmic rays with energies above 10(18) eV. It is a hybrid facility that employs a Fluorescence Detector to perform nearly calorimetric measurements of Extensive Air Shower energies. To obtain reliable calorimetric information from the FD, the atmospheric conditions at the observatory need to be continuously monitored during data acquisition. In particular, light attenuation due to aerosols is an important atmospheric correction. The aerosol concentration is highly variable, so that the aerosol attenuation needs to be evaluated hourly. We use light from the Central Laser Facility, located near the center of the observatory site, having an optical signature comparable to that of the highest energy showers detected by the FD. This paper presents two procedures developed to retrieve the aerosol attenuation of fluorescence light from CLF laser shots. Pracoviště Fyzikální ústav Kontakt Kristina Potocká, potocka@fzu.cz, Tel.: 220 318 579 Rok sběru 2014
Počet záznamů: 1