Determination of antibiotics in influents and effluents of wastewater-treatment-plants in the Czech Republic – development and application of the SPE and a UHPLC-ToFMS method

  1. 1.
    SYSNO ASEP0395780
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevDetermination of antibiotics in influents and effluents of wastewater-treatment-plants in the Czech Republic – development and application of the SPE and a UHPLC-ToFMS method
    Tvůrce(i) Tylová, Tereza (MBU-M)
    Flieger, Miroslav (MBU-M) ORCID
    Olšovská, Jana (MBU-M)
    Zdroj.dok.Analytical Methods: advancing methods and applications . - : Royal Society of Chemistry - ISSN 1759-9660
    Roč. 5, č. 8 (2013), s. 2110-2118
    Poč.str.9 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaTANDEM MASS-SPECTROMETRY ; PERFORMANCE LIQUID-CHROMATOGRAPHY ; ANTIMICROBIAL CONSUMPTION ESAC
    Vědní obor RIVCB - Analytická chemie, separace
    CEP1M06011 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaMBU-M - RVO:61388971
    UT WOS000316960200031
    DOI10.1039/c3ay00048f
    AnotaceA method consisting of solid phase extraction followed by ultra-high performance liquid chromatography combined with time-of-flight mass spectrometry (UHPLC-ToFMS) has been developed for the determination of multiple-class antibiotics in influents and effluents of wastewater-treatment-plants (WWTPs). The nineteen analyzed antibiotics belong to the 5 most prescribed antibiotic classes in the Czech Republic, namely tetracyclines, macrolides, sulfonamides, fluoroquinolones, and lincosamides. The matrix-matched calibration technique with internal standard addition for each antibiotic group was employed for quantification. Two extractions employing an Oasis HLB cartridge and two injections were needed for each sample due to the different physico-chemical properties of the tested antibiotics. Prior to the extraction on the Oasis HLB SPE cartridge, the samples were adjusted to pH 4.5 and 7.5. The usefulness and versatility of the method was documented by achieving method limits of quantification up to 10 ng L-1 and recoveries >80% for most analytes