Počet záznamů: 1  

Ultra-stable implanted Rb-83/Kr-83m electron sources for the energy scale monitoring in the KATRIN experiment

  1. 1.
    SYSNO ASEP0392291
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevUltra-stable implanted Rb-83/Kr-83m electron sources for the energy scale monitoring in the KATRIN experiment
    Tvůrce(i) Zbořil, Miroslav (UJF-V) ORCID
    Bauer, S. (DE)
    Beck, M. (DE)
    Bonn, J. (DE)
    Dragoun, Otokar (UJF-V) RID, SAI
    Jakoubek, J. (CZ)
    Johnston, K. (CH)
    Kovalík, Alojz (UJF-V) RID, ORCID, SAI
    Otten, E. W. (DE)
    Schlosser, K. (DE)
    Slezák, Martin (UJF-V) RID, ORCID
    Špalek, Antonín (UJF-V) RID
    Thummler, T. (DE)
    Vénos, Drahoslav (UJF-V) RID, SAI, ORCID
    Žemlička, J. (CZ)
    Weinheimer, C. (DE)
    Celkový počet autorů16
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 8, č. 3 (2013), P03009
    Poč.str.30 s.
    Forma vydáníTištěná - P
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovalasers ; sources ; particle-beams ; spectrometers
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    CEPGAP203/12/1896 GA ČR - Grantová agentura ČR
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000316990700034
    DOI10.1088/1748-0221/8/03/P03009
    AnotaceThe KATRIN experiment aims at the direct model-independent determination of the average electron neutrino mass via the measurement of the endpoint region of the tritium beta decay spectrum. The electron spectrometer of the MAC-E filter type is used, requiring very high stability of the electric filtering potential. This work proves the feasibility of implanted Rb-83/Kr-83m calibration electron sources which will be utilised in the additional monitor spectrometer sharing the high voltage with the main spectrometer of KATRIN. The source employs conversion electrons of Kr-83m which is continuously generated by Rb-83. The K-32 conversion line (kinetic energy of 17.8 keV, natural line width of 2.7 eV) is shown to fulfill the KATRIN requirement of the relative energy stability of +/- 1.6 ppm/month. The sources will serve as a standard tool for continuous monitoring of KATRIN's energy scale stability with sub-ppm precision. They may also be used in other applications where the precise conversion lines can be separated from the low energy spectrum caused by the electron inelastic scattering in the substrate.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2014
    Elektronická adresahttp://iopscience.iop.org/1748-0221/8/03/P03009/pdf/1748-0221_8_03_P03009.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.