Počet záznamů: 1  

Quantitative evaluation of freeze-substitution effects on preservation of nuclear antigens during preparation of biological samples for immunoelectron microscopy

  1. 1.
    SYSNO ASEP0387826
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevQuantitative evaluation of freeze-substitution effects on preservation of nuclear antigens during preparation of biological samples for immunoelectron microscopy
    Tvůrce(i) Sobol, Margaryta (UMG-J) RID
    Philimonenko, Vlada (UMG-J)
    Philimonenko, Anatoly (UMG-J)
    Hozák, Pavel (UMG-J) RID, ORCID
    Zdroj.dok.Histochemistry and Cell Biology. - : Springer - ISSN 0948-6143
    Roč. 138, č. 1 (2012), s. 167-177
    Poč.str.11 s.
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovaimmuno-gold labeling ; automated freeze-substitution ; LR White ; immunohistochemistry ; high-pressure freezing
    Vědní obor RIVEB - Genetika a molekulární biologie
    CEPKAN200520704 GA AV ČR - Akademie věd
    2B06063 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LC545 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GAP305/11/2232 GA ČR - Grantová agentura ČR
    CEZAV0Z50520514 - UMG-J (2005-2011)
    UT WOS000305222300013
    DOI10.1007/s00418-012-0931-6
    AnotaceUsing quantitative evaluation of immuno-gold labeling and antigen content, we evaluated various automated freeze-substitution protocols used in preparation of biological samples for immunoelectron microscopy. Protein extraction from cryoimmobilized cells was identified as a critical point during the freeze-substitution. The loss of antigens (potentially available for subsequent immuno-gold labeling) was not significantly affected by freezing, while the cryosubstitution with an organic solvent caused a significant loss of antigens. While addition of water can improve visibility of some cell structures, it strengthened the negative effect of cryosubstitution on antigen loss by extraction. This was, however, significantly reversed in the presence of 0.5% glutaraldehyde in the substitution medium. Furthermore, we showed that the level of these changes was antigen-dependent. In conclusion, low concentrations of glutaraldehyde can be generally recommended for cryosubstitution rather than the use of pure solvent, but the exact conditions need to be elaborated individually for certain antigens.
    PracovištěÚstav molekulární genetiky
    KontaktNikol Škňouřilová, nikol.sknourilova@img.cas.cz, Tel.: 241 063 217
    Rok sběru2013
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.