Počet záznamů: 1  

The structural changes in polymers PEEK, PET and PI Implanted Co+ low energy ions

  1. 1.
    SYSNO ASEP0382665
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVZáznam nebyl označen do RIV
    NázevThe structural changes in polymers PEEK, PET and PI Implanted Co+ low energy ions
    Tvůrce(i) Macková, Anna (UJF-V) RID, ORCID, SAI
    Malinský, Petr (UJF-V) RID, ORCID, SAI
    Mikšová, Romana (UJF-V) RID, ORCID, SAI
    Toms, Petr (UJF-V)
    Khaibullin, R. I. (RU)
    Valeev, V. F. (RU)
    Švorčík, V. (CZ)
    Slepička, P. (CZ)
    Celkový počet autorů8
    Zdroj.dok.Program and Abstract Book. -, 2012
    Rozsah strans. 1-8
    Poč.str.1 s.
    AkceThe 18th International Conference on Ion Beam Modifications of Materials
    Datum konání02.09.2012-07.09.2012
    Místo konáníQingdao
    ZeměCN - Čína
    Jazyk dok.eng - angličtina
    Země vyd.CN - Čína
    Klíč. slovapolymers ; implantations ; RBS ; ERDA
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    Vědní obor RIV – spolupráceElektronika a optoelektronika, elektrotechnika
    CEPGBP108/12/G108 GA ČR - Grantová agentura ČR
    Institucionální podporaUJF-V - RVO:61389005
    AnotaceIon irradiation of polymers is followed by the processes of macromolecular destruction, cross-linking, free radicals formation, carbonization and oxidation. High fluence implantation of metal ions can be used to fabricate metal-doped polymer films, which are applicable in electronics due to their high electric conductivity and field electron emission capacity. Specimens of polyimide (PI), polyetheretherketone (PEEK), and polyethyleneterephtalate (PET) were implanted by 80 keV Co+ ions at room temperature at fluences (0.2x1016 – 1.0x1017) cm–2 and annealed at temperatures below and close to Tg up to 300°C. Changes in the chemical composition and implanted depth profiles in polymers induced by high fluence metal ions irradiation and additional annealing have been studied using RBS and ERDA techniques. Structural changes of the polymers were characterised by the UV–vis spectroscopy. A significant hydrogen release from the polymer surface layer was observed along with significant changes in the surface layer composition. The UV–vis results indicated an increase in the concentration and conjugation of double bonds. Surface morphology was analysed by AFM. The changes in the polymer sheet resistance of the implanted and annealed samples were measured by standard two-point technique.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2013
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.