Počet záznamů: 1  

Microradiagraphy of biological samples with Timepix

  1. 1.
    SYSNO ASEP0379076
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevMicroradiagraphy of biological samples with Timepix
    Tvůrce(i) Dammer, J. (CZ)
    Weyda, František (BC-A)
    Beneš, J. (CZ)
    Sopko, V. (CZ)
    Jakůbek, J. (CZ)
    Vondráček, V. (CZ)
    Celkový počet autorů6
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 6, C11005 (2011), s. 1-6
    Poč.str.6 s.
    AkceInternational workshop on radiation imaging detectors /13./
    Datum konání03.07.2011-07.07.2011
    Místo konáníZurich
    ZeměCH - Švýcarsko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaX-ray detectors ; X-ray radiography and digital radiography (DR) ; pixelated detectors and associated VLSI electronics
    Vědní obor RIVEA - Morfologické obory a cytologie
    CEP2B06005 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z50070508 - ENTU-I, BC-A (2005-2011)
    UT WOS000298320400005
    DOI10.1088/1748-0221/6/11/C11005
    AnotaceMicroradiography is an imaging technique using X-rays in the study of internal structures of objects. This rapid and convenient imaging tool is based on differential X-ray attenuation by various tissues and structures within the biological sample. The non-absorbed radiation is detected with a suitable detector and creates a radiographic image. In order to detect the differential properties of X-rays passing through structures sample with different compositions, an adequate high-quality imaging detector is needed. We describe the recently developed radiographic apparatus, equipped with Timepix semiconductor pixel detector. The detector is used as an imager that counts individual photons of ionizing radiation, emitted by an X-ray tube FeinFocus with tungsten, copper or molybdenum anode. Thanks to the wide dynamic range, time over threshold mode-counter is used as Wilkinson type ADC allowing direct energy measurement in each pixel of Timepix detector and its high spatial resolution better than 1 m m, the setup is particularly suitable for radiographic imaging of small biological samples. We are able to visualize some internal biological processes and also to resolve the details of insects (morphology) using different anodes. These anodes generate different energy spectra. These spectra depend on the anode material. The resulting radiographic images varies according to the selected anode. Tiny live insects are an ideal object for our studies.
    PracovištěBiologické centrum (od r. 2006)
    KontaktDana Hypšová, eje@eje.cz, Tel.: 387 775 214
    Rok sběru2013
    Elektronická adresahttp://iopscience.iop.org/1748-0221/6/11/C11005/pdf/1748-0221_6_11_C11005.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.