Počet záznamů: 1  

Personnel protection during the operation of Thomson scattering laser system on COMPASS tokamak

  1. 1.
    SYSNO ASEP0365132
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevPersonnel protection during the operation of Thomson scattering laser system on COMPASS tokamak
    Tvůrce(i) Böhm, Petr (UFP-V) RID
    Hron, Martin (UFP-V) RID, ORCID
    Kovar, J. (CZ)
    Sova, J. (CZ)
    Zvolanek, M. (CZ)
    Aftanas, Milan (UFP-V) RID
    Bílková, Petra (UFP-V) RID
    Pánek, Radomír (UFP-V) RID
    Walsh, M.J. (FR)
    Zdroj.dok.Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
    Roč. 86, 6-8 (2011), s. 699-702
    Poč.str.4 s.
    Forma vydáníweb - web
    AkceSymposium on Fusion Technology, SOFT-26/26th./
    Datum konání27.09.2010-01.10.2010
    Místo konáníPorto
    ZeměPT - Portugalsko
    Typ akceEUR
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaTokamak ; Thomson scattering ; Laser safety ; Personnel protection ; PLC
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEPGA202/09/1467 GA ČR - Grantová agentura ČR
    GD202/08/H057 GA ČR - Grantová agentura ČR
    7G09042 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z20430508 - UFP-V (2005-2011)
    UT WOS000297426500052
    DOI10.1016/j.fusengdes.2011.02.073
    AnotaceA recently installed Thomson scattering diagnostic on COMPASS tokamak uses two high power lasers. The presented protection system ensures laser safety of the personnel. Protection covers three areas–laser laboratory, spectrometer laboratory and tokamak hall. Laser protection system inputs are controlling the covering of the laser beam path, the entrance doors, the beam shutters and the laser cooling. Six regimes are defined for the protection system, covering all operation of the laser system, including laser service and low power beam alignment. Hardware implementation of the protection is based on PLC. The system is controlled via PCs with a touch screen. Connection to the COMPASS personnel protection system is described.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2012
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.