Počet záznamů: 1  

Experimental study of high rayleigh number convection using cryogenic gaseous 4He

  1. 1.
    SYSNO ASEP0352309
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevExperimental study of high rayleigh number convection using cryogenic gaseous 4He
    Tvůrce(i) Urban, Pavel (UPT-D) RID, ORCID, SAI
    Musilová, Věra (UPT-D) RID, SAI, ORCID
    Skrbek, L. (CZ)
    Celkový počet autorů3
    Zdroj.dok.Proceedings of the International Conference Experimental Fluid Mechanics 2010. - Liberec : Technical University of Liberec, 2010 / Vít T. ; Dančová P. - ISBN 978-80-7372-670-6
    Rozsah strans. 762-769
    Poč.str.8 s.
    AkceExperimental Fluid Mechanics 2010 -EFM10
    Datum konání24.11.2010-26.11.2010
    Místo konáníLiberec
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaRayleigh number ; turbulent thermal convection ; Kraichnan regime ; convection
    Vědní obor RIVBJ - Termodynamika
    CEPKJB200650902 GA AV ČR - Akademie věd
    GA202/05/0218 GA ČR - Grantová agentura ČR
    ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z20650511 - UPT-D (2005-2011)
    AnotaceSeveral laboratories worldwide try to elucidate the underlying mechanisms of turbulent thermal convection using cryogenic He gas, a working fluid with truly remarkable and widely tuneable properties. The focus is on the efficiency of the heat transfer, experimentally studied via the Nusselt (Nu) versus Rayleigh number (Ra) dependence, especially at very high Ra. In order to resolve existing controversies among published results, we designed and built a cryogenic apparatus capable of reaching Ra up to 2 × 10e15, thus covering the range of interest where various transitions such as that into the theoretically predicted ultimate Kraichnan regime have been claimed. The cylindrical convection cell of 300 mm both in diameter and height is designed to withstand pressures up to 250 kPa at working temperatures between 4.2 K and 12 K. The main advantage of this apparatus is minimized influence of its cell design and materials used on the studied convection. The first experimental results are resented.