Monitor of mirror distance of Fabry-Perot cavity by the use of stabilized femtosecond laser comb

  1. 1.
    SYSNO ASEP0352204
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevMonitor of mirror distance of Fabry-Perot cavity by the use of stabilized femtosecond laser comb
    Tvůrce(i) Šmíd, Radek (UPT-D) RID, SAI
    Ježek, Jan (UPT-D) RID, ORCID, SAI
    Buchta, Zdeněk (UPT-D) RID, SAI, ORCID
    Čížek, Martin (UPT-D) RID, ORCID, SAI
    Mikel, Břetislav (UPT-D) RID, SAI
    Lazar, Josef (UPT-D) RID, ORCID, SAI
    Číp, Ondřej (UPT-D) RID, SAI, ORCID
    Celkový počet autorů7
    Zdroj.dok.17th Slovak-Czech-Polish Optical Conference on Wave and Quantum Aspects of Contemporary Optics (Proceedings of SPIE Vol. 7746). - Bellingham : SPIE, 2010 - ISBN 978-0-8194-8236-5
    Rozsah stran77460i: 1-8
    Poč.str.8 s.
    AkceSlovak-Czech-Polish Optical Conference on Wave and Quantum Aspects of Contemporary Optics /17./
    Datum konání06.09.2010
    Místo konáníLiptovsky Jan
    ZeměSK - Slovensko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovalength standard ; femtosecond laser ; stabilization ; Fabry-Perot cavity
    Vědní obor RIVBH - Optika, masery a lasery
    CEPLC06007 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    2A-1TP1/127 GA MPO - Ministerstvo průmyslu a obchodu
    GAP102/10/1813 GA ČR - Grantová agentura ČR
    CEZAV0Z20650511 - UPT-D (2005-2011)
    UT WOS000291389400018
    AnotaceThe use of an ultra low expansion cavity plays a crucial role in laser stabilization, and in atomic or ion clocks. We propose an easy method of precise monitoring of optical path distance in Fabry-Perot interferometer. The spacing of mirrors of the Fabry-Perot interferometer in ambient air represents the optical path distance referenced to stable optical frequency of the femtosecond mode-locked laser. With the help of highly selective optical filter it is possible to get only a few of separate spectral components of laser comb. Optical path distance is transfered to optical frequency of the comb component and through the repetition frequency of the laser to the radio-frequency domain. Repetition frequency of the laser can be monitored with the uncertainty referenced to the any local oscillator or through the GPS to the atomic clock standard.