Počet záznamů: 1  

EDICAM fast video diagnostic installation on the COMPASS tokamak

  1. 1.
    SYSNO ASEP0349226
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevEDICAM fast video diagnostic installation on the COMPASS tokamak
    Tvůrce(i) Szappanos, A. (HU)
    Berta, M. (HU)
    Hron, Martin (UFP-V) RID, ORCID
    Pánek, Radomír (UFP-V) RID
    Stöckel, Jan (UFP-V) RID
    Veres, G. (HU)
    Weinzettl, Vladimír (UFP-V) RID, ORCID
    Zoletnik, S. (HU)
    Tulipán, S. (HU)
    Zdroj.dok.Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
    Roč. 85, 3-4 (2010), s. 370-373
    Poč.str.4 s.
    Forma vydáníweb - web
    AkceIAEA Technical Meeting on Control, Data Acquisition and Remote Participation for Fusion Research/7th./
    Datum konání15.06.2009-19.06.2009
    Místo konáníAix – en – Provence
    ZeměFR - Francie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaVideo diagnostic ; Fast data processing ; CMOS sensor ; Image processing
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    CEZAV0Z20430508 - UFP-V (2005-2011)
    UT WOS000281190000021
    DOI10.1016/j.fusengdes.2009.11.001
    AnotaceA new camera system ‘event detection intelligent camera’ (EDICAM) is being developed by the Hungarian Association and has been installed on the COMPASS tokamak in the IPP AS CR in Prague. The standalone system contains a data acquisition PC and a prototype sensor module of EDICAM. Appropriate optical system have been designed and adjusted for the local requirements, and a mechanical holder keeps the camera out of the magnetic field. The fast camera contains a monochrome CMOS sensor with advanced control features and spectral sensitivity in the visible range. A special web based control interface has been implemented using Java spring framework to provide the control features in a graphical user environment. Java native interface (JNI) is used to reach the driver functions and to collect the data stored by direct memory access (DMA). The control system contains basic image processing features and the 3D wireframe of the tokamak can be projected to the selected frames.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2011
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.