Methods of Conversion of Stability of Femtosecond Stabilized Mode-locked Laser to Optical Resonator

  1. 1.
    SYSNO ASEP0336313
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevMethods of Conversion of Stability of Femtosecond Stabilized Mode-locked Laser to Optical Resonator
    Tvůrce(i) Šmíd, Radek (UPT-D) RID, SAI
    Číp, Ondřej (UPT-D) RID, SAI, ORCID
    Lazar, Josef (UPT-D) RID, ORCID, SAI
    Celkový počet autorů3
    Zdroj.dok.EFTF - IFCS 2009. - Los Alamitos : IEEE, 2009 - ISSN 1075-6787 - ISBN 978-1-4244-3510-4
    Rozsah strans. 742-746
    Poč.str.5 s.
    AkceEuropean Frequency and Time Forum /23./ and International Frequency Control Symposium /63./
    Datum konání20.03.2009-24.03.2009
    Místo konáníBesancon
    ZeměFR - Francie
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovalaser ; Fabry-Perot ; interferometer ; length etalon ; stabilized optical comb
    Vědní obor RIVBH - Optika, masery a lasery
    CEPGA102/09/1276 GA ČR - Grantová agentura ČR
    LC06007 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    2C06012 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    2A-1TP1/127 GA MPO - Ministerstvo průmyslu a obchodu
    FT-TA3/133 GA MPO - Ministerstvo průmyslu a obchodu
    2A-3TP1/113 GA MPO - Ministerstvo průmyslu a obchodu
    GA102/07/1179 GA ČR - Grantová agentura ČR
    CEZAV0Z20650511 - UPT-D (2005-2011)
    UT WOS000274814900153
    AnotaceIn this work we propose three methods of a conversion of RF clock stability to the length precision using fs stabilized laser via Fabry-Perot by three proven conversion techniques. One mode stabilized lasers could provide optical frequency reference. Stability of such a laser could be transferred to length etalon represented by optical interferometer.We present using of Fabry-Perot interferometer as a length etalon referenced to fs stabilized optical comb. The train of femtosecond pulses produces equidistant optical frequencies separated by repetition frequency and shifted by an offset frequency. Both frequencies are stabilized according to widely used f-to-2f stabilization method to RF frequency standard, i.e. atomic clocks represented by GPS controlled signal with relative stability down to 10E-15.