Počet záznamů: 1  

A comparative study on ganglioside micelles using electronic energy transfer, fluorescence correlation spectroscopy and light scattering techniques

  1. 1.
    SYSNO ASEP0333803
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevA comparative study on ganglioside micelles using electronic energy transfer, fluorescence correlation spectroscopy and light scattering techniques
    Překlad názvuStudie micel tvořených GM1 gangliosidy za použití elektronického přenosu energie, fluorescenční korelační spektroskopie a rozptylu světla
    Tvůrce(i) Šachl, Radek (UFCH-W) RID, ORCID
    Mikhalyov, I. (RU)
    Hof, Martin (UFCH-W) RID, ORCID
    Johansson, L. B. A. (SE)
    Zdroj.dok.Physical Chemistry Chemical Physics. - : Royal Society of Chemistry - ISSN 1463-9076
    Roč. 11, č. 21 (2009), s. 4335-4343
    Poč.str.9 s.
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaatomic-force microscopy ; Alzheimers disease ; precise measurement
    Vědní obor RIVCF - Fyzikální chemie a teoretická chemie
    CEPLC06063 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GD203/05/H001 GA ČR - Grantová agentura ČR
    CEZAV0Z40400503 - UFCH-W (2005-2011)
    UT WOS000266269200025
    DOI10.1039/b821658d
    AnotaceGanglioside (G(M1)) micelles have been studied by means of three different techniques: fluorescence correlation spectroscopy (FCS), electronic energy transfer, as monitored by time-resolved fluorescence spectroscopy, as well as static and dynamic light scattering. The aggregation numbers obtained, 168 +/- 4, remain constant over a wide range of G(M1) concentrations (0.764-156 mu M), are very consistent when using dfferent donor-acceptor energy transfer pairs and have served as reference values in tests of the FCS method. It is recommended to calibrate the focal volume by using known dye concentrations. For this the rhodamine dye, 5-TAMRA, turns out to be most suitable. It is also shown that FCS provides correct values of the aggregation numbers, provided that the focal volume is calibrated by using updated values of the diffusion constant of Rhodamine 6G. These results also support recent methodological advances in FCS.
    PracovištěÚstav fyzikální chemie J.Heyrovského
    KontaktMichaela Knapová, michaela.knapova@jh-inst.cas.cz, Tel.: 266 053 196
    Rok sběru2010
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.