Počet záznamů: 1  

RBS, UV-VIS and XPS characterization of 40 keV Ni+ implanted PEEK, PET and PI

  1. 1.
    SYSNO ASEP0315789
    Zařazení RIVZáznam nebyl označen do RIV
    NázevRBS, UV-VIS and XPS characterization of 40 keV Ni+ implanted PEEK, PET and PI
    Překlad názvuRBS, UV-VIS a XPS charakterizace Ni+ 40 keV implantovaných polymerů PEEK, PET a PI
    Tvůrce(i) Macková, Anna (UJF-V) RID, ORCID, SAI
    Bočan, Jiří (UJF-V)
    Khaibullin, R. I. (RU)
    Švorčík, V. (CZ)
    Slepička, P. (CZ)
    Siegel, J. (CZ)
    Valeev, V. F. (RU)
    Zdroj.dok.16th International Conference on Ion Beam Modification of Materials Book of Abstracts. - Dresden : Institute of Ion Beam Physics and Materials Research, Forschungzentrum Dresden-Rossendorf, 2008
    S. 317-317
    Poč.str.1 s.
    Akce16th International Conference on Ion Beam Modification of Materials
    Datum konání31.08.2008-05.09.2008
    Místo konáníDresden
    ZeměDE - Německo
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovaion implantation in polymers ; TRIDYN ; Ion Beam Analysis ; UV-VIS, XPS
    Vědní obor RIVJI - Kompozitní materiály
    CEPKJB100480601 GA AV ČR - Akademie věd
    LC06041 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    CEZAV0Z10480505 - UJF-V (2005-2011)
    AnotacePolyimide (PI), polyetheretherketone (PEEK), and polyethyleneterephtalate (PET) were implanted with 40 keV Ni+ ions at room temperature at fluences from 1,0 . 1016 ions cm-2 to 1,5 . 1017 ions cm-2 and at different ion currents from 4microA to 10microA. The depth profiles of implanted Ni atoms determined by RBS technique are compared with those predicted by SRIM and TRIDYN codes. Hydrogen depletion as a function of the ion fluence was determined by ERDA technique and compositional and structural changes of the polymers were characterized by UV-VIS and XPS methods. The implanted profiles differ significantly from those predicted by the SRIM code and for lower fluences they can satisfactorily be described by the TRIDYN simulation. A significant hydrogen escape is observed from the polymer surface layer together with significant changes in the surface layer composition. UV-VIS results indicate an increase in the concentration and conjugation of double bonds.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2009
Počet záznamů: 1  