Počet záznamů: 1  

Precision half-life measurement of .sup.140 La with Ge-detector

  1. 1.
    SYSNO ASEP0185523
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JOstatní články
    NázevPrecision half-life measurement of .sup.140 La with Ge-detector
    Tvůrce(i) Adam, Jindřich (UJF-V) RID
    Belov, A. G. (RU)
    Brandt, R. (DE)
    Chaloun, P. (CZ)
    Honusek, Milan (UJF-V)
    Kalinnikov, V. G. (RU)
    Krivopustov, M. I. (RU)
    Kulakov, B. A. (RU)
    Langrock, E. J. (DE)
    Pronskikh, V. S. (RU)
    Sosnin, A. N. (RU)
    Stegailov, V. I. (RU)
    Tsoupko-Sitnikov, V. M. (RU)
    Wan, J. S. (DE)
    Westmeier, W. (DE)
    Zdroj.dok.Nuclear Instruments & Methods in Physics Research Section B. - : Elsevier - ISSN 0168-583X
    Roč. 187, - (2002), s. 419-426
    Poč.str.8 s.
    Jazyk dok.eng - angličtina
    Země vyd.NL - Nizozemsko
    Klíč. slovaradioastive nuclei ; Ge-detectors ; half-life measurements
    Vědní obor RIVBG - Jaderná, atomová a mol. fyzika, urychlovače
    CEPKSK1048102 GA AV ČR - Akademie věd
    AnotaceHalf-life is one of the fundamental properties od radioactive nuclei, and the presision required for its numerous applications in modern physics sometimes approaches the level of 10.sup.-4 -10.sup.-5. Most part of the T.sub.1/2 measurements performed up to now was made with proportional chambers, and the results were sometimes hardly reproducible within the error limits. Using Ge-detectors for that purpose brought some significant advantages but electronic unit related effects and spectra analysis procedures still remain the sources of the errors influencing the accuracy of the T.sub.1/2 attained. In this work, .sup.140 La sampleswere obtained in the .sup.139 La(n,ç).sup.140 La reastion,employing a microtron as a neutron source and the half-life measurements were performed with a HPGe-detector. Influencing factors such a photopeak and background shape, electronic circuitry dead time and deadtime variations during the measurements, as well as pulse pileup are studied altogether. Values of the .sup.140 La T.sub.1/2 = 1.6808(18) d,ŕ = 0.47749(20) x 10.sub.-5, agreeing within the uncertainities with the most accurate evaluated ones (T.sup.1/2 = 1.6781(3) d,ŕ = 0.47807(9) x 10.sub.-5) (2) were obtained in two series of measurements.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2003

Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.