Quadrupole lens-free multiple-profile diagnostics for emittance measurement of laser wakefield accelerated electron beams

  1. 1.
    0466848 - FZÚ 2017 RIV NL eng J - Článek v odborném periodiku
    Krůs, Miroslav - Laštovička, Tomáš - Levato, Tadzio
    Quadrupole lens-free multiple-profile diagnostics for emittance measurement of laser wakefield accelerated electron beams.
    Nuclear Instruments & Methods in Physics Research Section A. Roč. 810, Feb (2016), s. 32-36. ISSN 0168-9002. E-ISSN 1872-9576
    Grant CEP: GA MŠMT ED1.1.00/02.0061; GA MŠMT EE2.3.20.0279
    GRANT EU: European Commission(XE) 284464 - LASERLAB-EUROPE
    Grant ostatní: ELI Beamlines(XE) CZ.1.05/1.1.00/02.0061; LaserZdroj (OP VK 3)(XE) CZ.1.07/2.3.00/20.0279; AVČR(CZ) M100101210
    Institucionální podpora: RVO:68378271
    Klíčová slova: scattering * plasma
    Kód oboru RIV: BL - Fyzika plazmatu a výboje v plynech
    Impakt faktor: 1.362, rok: 2016

    A quadrupole lens-free diagnostic is a simple single shot method which can be used to measure the electron beam transverse emittance. LANEX screens are used as profile monitors due to the high yield of visible photons which can be easily detected by standard camera sensors. This type of minimally destructive diagnostics is particularly suitable for electron beams accelerated by the laser wakefield mechanism where the basic parameters of such beams fluctuate shot-to-shot mainly during the beam optimizing process.
    Trvalý link: http://hdl.handle.net/11104/0265058

     
     