Počet záznamů: 1
Use of a novel transfer function to reduce repolarization interval hysteresis
- 1.0350809 - ÚPT 2011 RIV US eng J - Článek v odborném periodiku
Halámek, Josef - Jurák, Pavel - Bunch, T.J. - Lipoldová, J. - Novák, M. - Vondra, Vlastimil - Leinveber, Pavel - Plachý, M. - Kára, T. - Villa, M. - Fráňa, P. - Souček, M. - Somers, V. K. - Asirvatham, S.J.
Use of a novel transfer function to reduce repolarization interval hysteresis.
Journal of Interventional Cardiac Electrophysiology. Roč. 29, č. 1 (2010), s. 23-32. ISSN 1383-875X. E-ISSN 1572-8595
Grant CEP: GA ČR GA102/08/1129
Výzkumný záměr: CEZ:AV0Z20650511
Klíčová slova: QT hysteresis * QT/RR coupling * Transfer function * Long QT syndrome
Kód oboru RIV: FA - Kardiovaskulární nemoci vč. kardiochirurgie
Impakt faktor: 1.228, rok: 2010
ardiac repolarization is assessed by the QT interval on the surface electrocardiogram and varies with the heart rate. Standard QT corrections (QTc) do not account for the lag in QT change following a change in heart rate (QT hysteresis). Our group has developed and tested a transfer function (TRF) model to assess the effectiveness of a dynamic model of QT/RR coupling in eliminating hysteresis.
Trvalý link: http://hdl.handle.net/11104/0190712
Počet záznamů: 1