Analysis of microcracks caused by drop shatter testing of porcine kidneys
- 1.0327877 - FGÚ 2010 RIV DE eng J - Článek v odborném periodiku
Tonar, Z. - Janáček, Jiří - Nedorost, L. - Grill, R. - Báča, V. - Záťura, F.
Analysis of microcracks caused by drop shatter testing of porcine kidneys.
[Analýza mikrotrhlin způsobených pádovým testem v ledvině vepře.]
Annals of Anatomy-Anatomischer Anzeiger. Roč. 191, č. 3 (2009), s. 294-308. ISSN 0940-9602. E-ISSN 1618-0402
Grant CEP: GA AV ČR(CZ) IAA100110502
Výzkumný záměr: CEZ:AV0Z50110509
Klíčová slova: kidney * rupture * stereology
Kód oboru RIV: FP - Ostatní lékařské obory
Impakt faktor: 0.877, rok: 2009
Cortex and medula were both damaged after drop shatter test, even in those areas of kidneys, that were free of macroscopic cracks on the surface. The ruptures propagated preferentially through the interstitial connective tissue. The most affected vessels were the arcuate veins followed by the arcuate arteries
Nejvýraznější změny kůry a dřeně ledvin po simulovaném traumatu jsou ruptury vedoucí přednostně řídkým kolagenním vazivem. Z cév byly nejvíce poškozené vv. arcutae, poškozené byly i aa. arcutae