Počet záznamů: 1  

Determination of chlorite, muscovite, albite and quartz in claystones and clay shales by infrared spectroscopy and partial least-squares regression

  1. 1.
    SYSNO ASEP0449356
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevDetermination of chlorite, muscovite, albite and quartz in claystones and clay shales by infrared spectroscopy and partial least-squares regression
    Tvůrce(i) Ritz, M. (CZ)
    Vaculíková, Lenka (UGN-S) RID, ORCID
    Plevová, Eva (UGN-S) RID, ORCID
    Matýsek, D. (CZ)
    Mališ, J. (CZ)
    Celkový počet autorů5
    Zdroj.dok.Acta geodynamica et geomaterialia. - : Ústav struktury a mechaniky hornin AV ČR, v. v. i. - ISSN 1214-9705
    Roč. 9, č. 4 (2012), s. 511-520
    Poč.str.10 s.
    Forma vydáníOnline - E
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Klíč. slovaclaystone and clay shale ; infrared spectroscopy ; chemometrics ; chlorite ; muscovite
    Vědní obor RIVCB - Analytická chemie, separace
    CEPED2.1.00/03.0082 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUGN-S - RVO:68145535
    UT WOS000312605700009
    AnotaceThe objective of this work is the chemometric quantification of minerals in rocks. A chemometric method was developed for the determination of chlorite, muscovite, albite and quartz in claystones and clay shales using infrared spectroscopy. Bromide pellets and diffuse reflectance were used to measure the infrared spectra; principal component analysis and partial least-squares regression were used as chemometric methods. Spectral regions (4000-3000 cm(-1) and 1300-400 cm(-1)) containing important spectral information were chosen by principal component analysis. The calibration models were created by a partial least-squares regression. The mean relative error and relative standard deviation were calculated for the assessment of accuracy and reproducibility. The value of the mean relative error was about 10 % for most of the calibration models. The value of the relative standard deviation ranged from 1.1 to 3.0 % for most calibration models based on diffuse reflectance spectra and from 4.0 to 9.2 % for most calibration models based on spectra obtained with bromide pellets.
    PracovištěÚstav geoniky
    KontaktLucie Gurková, lucie.gurkova@ugn.cas.cz, Tel.: 596 979 354
    Rok sběru2016
    Elektronická adresahttps://www.irsm.cas.cz/materialy/acta_content/2012_04/9.Ritz.pdf
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.