Počet záznamů: 1  

Size control of nanoparticles synthesized by pulsed laser ablation in liquids using donut-shaped beams

  1. 1.
    SYSNO ASEP0618796
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevSize control of nanoparticles synthesized by pulsed laser ablation in liquids using donut-shaped beams
    Tvůrce(i) Altakroury, A. R. (DE)
    Gatsa, Oleksandr (FZU-D) ORCID
    Riahi, F. (DE)
    Fu, Z.W. (DE)
    Flimelová, Miroslava (FZU-D) ORCID
    Samokhvalov, A. (DE)
    Barcikowski, S. (DE)
    Donate-Buendia, C. (DE)
    Bulgakov, Alexander V. (FZU-D) ORCID
    Goekce, B. (DE)
    Celkový počet autorů10
    Zdroj.dok.Beilstein Journal of Nanotechnology. - : Beilstein - Institut zur Foerderung der Chemischen Wissenschaften - ISSN 2190-4286
    Roč. 16, Mar (2025), s. 407-417
    Poč.str.11 s.
    Jazyk dok.eng - angličtina
    Země vyd.DE - Německo
    Klíč. slovabeam shaping ; cavitation bubble ; donut beam ; gold nanoparticles ; high-entropy alloy nanoparticles ; nanoparticle size analysis ; yttrium oxide nanoparticles
    Vědní obor RIVJJ - Ostatní materiály
    Obor OECDNano-materials (production and properties)
    CEPEH22_008/0004596 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    GF22-38449L GA ČR - Grantová agentura ČR
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    UT WOS001454077900001
    DOI https://doi.org/10.3762/bjnano.16.31
    AnotaceThe potential to modify the size distribution of nanoparticles synthesized by pulsed laser ablation in liquids is demonstrated using a donut-shaped laser beam. In experiments on pulsed laser ablation in water of gold, yttrium oxide, and high-entropy alloy targets with both Gaussian and donut-shaped beams, we observed a significant reduction in particle size, narrowing of the size distribution width, and an improvement in sphericity when utilizing the donut-shaped laser beam. We performed time-resolved shadowgraph imaging of the laser-induced cavitation bubble, revealing a toroidal structure that overruns the ring-shaped ablation site, compared to the quasi-hemispherical bubble covering the ablation spot produced by the Gaussian beam. Based on this pioneering study, further investigation with higher temporal and spatial resolution are warranted.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2026
    Elektronická adresahttps://hdl.handle.net/11104/0365731
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.