Počet záznamů: 1  

Exploring scintillators and Cherenkov radiators for MIP timing detectors

  1. 1.
    SYSNO ASEP0618721
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JOstatní články
    NázevExploring scintillators and Cherenkov radiators for MIP timing detectors
    Tvůrce(i) Cala', R. (CH)
    Martinazzoli, L. (CH)
    Kratochwil, N. (CH)
    Frank, I. (CH)
    Salomoni, M. (CH)
    Pagano, F. (CH)
    Terragni, G. (CH)
    Lowis, C. (CH)
    Chen, J. (CN)
    Pejchal, Jan (FZU-D) RID, ORCID
    Boháček, Pavel (FZU-D) RID, ORCID, SAI
    Nikl, Martin (FZU-D) RID, ORCID, SAI
    Tkachenko, S. (UA)
    Sidlestkiy, O. (UA)
    Paganoni, M. (IT)
    Pizzichemi, M. (CH)
    Auffray, E. (CH)
    Celkový počet autorů17
    Číslo článkuP04004
    Zdroj.dok.Journal of Instrumentation. - : Institute of Physics Publishing - ISSN 1748-0221
    Roč. 2025, č. 20 (2025)
    Poč.str.19 s.
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovacalorimeters ; Cherenkov detectors ; scintillators ; scintillation and light emission processes (solid, gas and liquid scintillators) ; timing detectors
    Vědní obor RIVBM - Fyzika pevných látek a magnetismus
    Obor OECDCondensed matter physics (including formerly solid state physics, supercond.)
    CEPEH23_020/0008525 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Způsob publikováníOpen access
    Institucionální podporaFZU-D - RVO:68378271
    DOI https://doi.org/10.1088/1748-0221/20/04/P04004
    AnotaceThis article presents the timing performance of materials with fast light emission, tested as Minimum Ionizing Particle detectors using 150 GeV hadron beams in Monte Carlo simulations and at the CERN SPS North Area. Pixels of cross-section 2 × 2mm2 or 3 × 3mm2 and length of 3 or 10mm were coupled to Hamamatsu SiPM and read out by fast high-frequency electronics. Materials whose timing performance relies on Cherenkov emission, namely BGSO, PWO, and PbF2, achieved time resolutions in the range 24–36 ps. Scintillators as L(Y)SO:Ce, GAGG, and BaF2 reached below 15 ps, the best topping at 12.1 ± 0.4 ps. These fast materials are compared to LYSO and their additional benefit is discussed. Given the promising results of BaF2, the study is completed with measurements of the scintillation properties of a set doped with yttrium to quench the slow light emission.
    PracovištěFyzikální ústav
    KontaktKristina Potocká, potocka@fzu.cz, Tel.: 220 318 579
    Rok sběru2026
    Elektronická adresahttps://hdl.handle.net/11104/0365550
Počet záznamů: 1  