Počet záznamů: 1  

Fluorescence confocal imaging via holographic endo-microscopy

  1. 1.
    SYSNO ASEP0568616
    Druh ASEPA - Abstrakt
    Zařazení RIVZáznam nebyl označen do RIV
    NázevFluorescence confocal imaging via holographic endo-microscopy
    Tvůrce(i) Tučková, Tereza (UPT-D) ORCID
    Pikálek, Tomáš (UPT-D) RID, ORCID, SAI
    Jákl, Petr (UPT-D) RID, ORCID, SAI
    Turtaev, S. (DE)
    Šiler, Martin (UPT-D) RID, ORCID, SAI
    Ondráčková, Petra (UPT-D)
    Krejčí, Jana (BFU-R) RID, ORCID
    Uhlířová, Hana (UPT-D) ORCID, RID
    Čižmár, Tomáš (UPT-D) RID, ORCID, SAI
    Zdroj.dok.16th Multinational Congress on Microscopy, 16MCM, 04-09 September 2022, Brno, Czech Republic. Book of abstracts. - Brno : Czechoslovak Microscopy Society, 2022 / Krzyžánek V. ; Hrubanová K. ; Hozák P. ; Müllerová I. ; Šlouf M. - ISBN 978-80-11-02253-2
    S. 278
    Poč.str.1 s.
    Forma vydáníOnline - E
    AkceMultinational Congress on Microscopy /16./
    Datum konání04.09.2022 - 09.09.2022
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.CZ - Česká republika
    Vědní obor RIVBH - Optika, masery a lasery
    Obor OECDOptics (including laser optics and quantum optics)
    CEPEF15_003/0000476 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUPT-D - RVO:68081731 ; BFU-R - RVO:68081707
    AnotaceIn biological research, there is a desire to image and study cellular processes in deep areas of the tissue. The tissue has strong scattering properties that limit the imaging depth when using light microscopy. The ability to relay light into deeper regions of the tissue has motivated the development of different types of endoscopes based on GRIN lenses, fiber bundles, or multi-mode fiber (MMF). Among those, the MMFs provide the best ratio between resolution and probe diameter. Thus they enable far-most atraumatic way of imaging up to unprecedented depth in the living brain tissue while achieving diffraction-limited resolution. However, the MMF acts as a turbid medium and the light after propagation comes out in a form of a random scrambled pattern. In order to counteract this scrambling, the light coupled into MMF can be modulated by spatial light modulators. In our case of MMF-based holographic endoscopy, the light is modulated using a digital micro-mirror device. At the distal end of the fiber, a single diffraction-limited spot is thus generated. This modulation enables imaging of the sample by scanning the spot across the field of view in the focal plane, similarly to a scanning microscope, and excites the fluorescence signal which is then collected by a bucket detector (PMT). However similarly to classical single photon excitation fluorescence microscopy, the images obtained through the MMF suffer from a decrease in contrast and resolution due to light scattered from out-of-focus planes. This effect is detrimental especially in highly-scattering dense tissue, such as the brain. In classical fluorescent microscopy, the out-of-focus light is suppressed using e.g. confocal approach. In the case of endoscopy, this confocal approach has also been demonstrated. However, it is not optimal for fluorescence in vivo imaging. We introduce a new concept of MMF-based confocal imaging which allows the suppression of out-of-focus light and attenuation of the background signal. As we here present on the imaging of the fluorescent phantom sample and fixed brain slices, confocal filtration increases the contrast and resolution of the resulting images.
    PracovištěÚstav přístrojové techniky