Počet záznamů: 1
Absolute frequencies of H13C14N hydrogen cyanide transitions in the 1.5-µm region with the saturated spectroscopy and a sub-kHz scanning laser
- 1.
SYSNO ASEP 0564702 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Absolute frequencies of H13C14N hydrogen cyanide transitions in the 1.5-µm region with the saturated spectroscopy and a sub-kHz scanning laser Tvůrce(i) Hrabina, Jan (UPT-D) RID, ORCID, SAI
Hošek, Martin (UPT-D)
Řeřucha, Šimon (UPT-D) RID, ORCID, SAI
Čížek, Martin (UPT-D) RID, ORCID, SAI
Pilát, Zdeněk (UPT-D) RID, SAI, ORCID
Zucco, M. (IT)
Lazar, Josef (UPT-D) RID, ORCID, SAI
Číp, Ondřej (UPT-D) RID, SAI, ORCIDCelkový počet autorů 8 Zdroj.dok. Optics Letters. - : Optical Society of America - ISSN 0146-9592
Roč. 47, č. 21 (2022), s. 5704-5707Poč.str. 4 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova laser spectroscopy ; saturated absorption spectroscopy ; laser standard ; frequency stability Vědní obor RIV BH - Optika, masery a lasery Obor OECD Optics (including laser optics and quantum optics) CEP EF16_026/0008460 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy ED0017/01/01 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LO1212 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora UPT-D - RVO:68081731 UT WOS 000903999200003 EID SCOPUS 85141150317 DOI 10.1364/OL.467633 Anotace The wide span and high density of lines in its rovibrational spectrum render hydrogen cyanide a useful spectroscopic media for referencing absolute frequencies of lasers in optical communication and dimensional metrology. We determined, for the first time to the best of our knowledge, the molecular transitions’ center frequencies of the H13C14N isotope in the range from 1526 nm to 1566 nm with 1.3 × 10−10 fractional uncertainty. We investigated the molecular transitions with a highly coherent and widely tunable scanning laser that was precisely referenced to a hydrogen maser through an optical frequency comb. We demonstrated an approach to stabilize the operational conditions needed to maintain the constantly low pressure of the hydrogen cyanide to carry out the saturated spectroscopy with the third-harmonic synchronous demodulation. We demonstrated approximately a forty-fold improvement in the line centers’ resolution compared to the previous result. Pracoviště Ústav přístrojové techniky Kontakt Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Rok sběru 2023 Elektronická adresa https://opg.optica.org/ol/fulltext.cfm?uri=ol-47-21-5704&id=513174
Počet záznamů: 1