Počet záznamů: 1
Methodology for Simultaneous Analysis of Photocatalytic deNO(x) Products
- 1.
SYSNO ASEP 0558893 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Methodology for Simultaneous Analysis of Photocatalytic deNO(x) Products Tvůrce(i) Suchánek, Jan (UFCH-W) RID, ORCID
Vaněčková, Eva (UFCH-W) SAI, ORCID
Dostál, Michal (UFCH-W) RID, ORCID, SAI
Mikysková, Eliška (UFCH-W)
Brabec, Libor (UFCH-W) RID, ORCID
Žouželka, Radek (UFCH-W) RID
Rathouský, Jiří (UFCH-W) RID, ORCIDČíslo článku 661 Zdroj.dok. Catalysts. - : MDPI
Roč. 12, č. 6 (2022)Poč.str. 9 s. Jazyk dok. eng - angličtina Země vyd. CH - Švýcarsko Klíč. slova photocatalysis ; air purification ; NOx ; hono ; no2 ; mass balance Vědní obor RIV CF - Fyzikální chemie a teoretická chemie Obor OECD Physical chemistry CEP GA19-12109S GA ČR - Grantová agentura ČR EF16_013/0001821 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Výzkumná infrastruktura NanoEnviCz II - 90124 - Ústav fyzikální chemie J. Heyrovského AV ČR, v. v. i. Způsob publikování Open access Institucionální podpora UFCH-W - RVO:61388955 UT WOS 000816439800001 EID SCOPUS 85132023771 DOI 10.3390/catal12060661 Anotace The ISO standard 22197-1:2016 used for the evaluation of the photocatalytic nitric oxide removal has a main drawback, which allows only the decrease of nitric oxide to be determined specifically. The remaining amount, expressed as ´´NO2´´, is considered as a sum of HNO3, HONO NO2, and other nitrogen-containing species, which can be potentially formed during the photocatalytic reaction. Therefore, we developed a new methodology combining our custom-made analyzers, which can accurately determine the true NO2 and HONO species, with the conventional NO one. Their function was validated via a photocatalytic experiment in which 100 ppbv of either NO or NO2 dispersed in air passed over (3 L min(-1)) an Aeroxide (c) TiO2 P25 surface. The gas-phase analysis was complemented with the spectrophotometric determination of nitrates (NO3-) and/or nitrites (NO2-) deposited on the P25 layer. Importantly, an almost perfect mass balance (94%) of the photocatalytic NOx abatement was achieved. The use of custom-made analyzers enables to obtain (i) no interference, (ii) high sensitivity, (iii) good linearity in the relevant concentration range, (iv) rapid response, and (v) long-term stability. Therefore, our approach enables to reveal the reaction complexity and is highly recommended for the photocatalytic NOx testing. Pracoviště Ústav fyzikální chemie J.Heyrovského Kontakt Michaela Knapová, michaela.knapova@jh-inst.cas.cz, Tel.: 266 053 196 Rok sběru 2023 Elektronická adresa http://hdl.handle.net/11104/0332389
Počet záznamů: 1