Počet záznamů: 1  

The MULTI spectrometer for measurement of beta-decay process in exotic nuclei

  1. 1.
    SYSNO ASEP0557384
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevThe MULTI spectrometer for measurement of beta-decay process in exotic nuclei
    Tvůrce(i) Siváček, Ivan (UJF-V)
    Stukalov, S. S. (RU)
    Sobolev, Yu. G. (RU)
    Testov, D. (RU)
    Smirnov, V. (RU)
    Penionzhkevich, Y. E. (RU)
    Zeinulla, Z. (KZ)
    Celkový počet autorů7
    Číslo článku01003
    Zdroj.dok.EPJ Web of Conferences, ANIMMA 2021 – Advancements in Nuclear Instrumentation Measurement Methods and their Applications, 253. - Les Ulis : E D P Sciences, 2021 - ISSN 2100-014X
    Poč.str.6 s.
    Forma vydáníTištěná - P
    AkceConference on Advancements in Nuclear Instrumentation Measurement Methods and their Applications (ANIMMA)
    Datum konání21.06.2021 - 25.06.2021
    Místo konáníPrague
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.FR - Francie
    Klíč. slovaMonte Carlo simulations ; Phoswich detector ; gamma-ray spectrometer ; He-3 neutron counters
    Obor OECDNuclear physics
    CEPLTT18021 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUJF-V - RVO:61389005
    UT WOS000788459400003
    DOI https://doi.org/10.1051/epjconf/202125301003
    AnotaceThe construction of the portable spectrometer, MULTI, is designed for the measurement of beta-gamma-neutron coincidences on beams of radioactive exotic nuclei. It will be used in measurements of the beta-decay process of neutron-rich nuclei with large Q(beta) values accessible in radioactive beams facilities. The experimental technique includes the measurement of the ratios between gamma-ray emission and multi-neutron emission, following beta-decay of radioactive nuclei implanted into an active target. The construction of a gamma-ray spectrometer based on high-volume CeBr3+NaI(Tl) phoswich scintillation detectors is introduced. Results of the measurements of its fundamental characteristics - total detection efficiency, peak efficiency and Compton suppression effect with a Co-60 source are presented. Design of the neutron counter array, consisting of 40 proportional counters filled with He-3 gas, was optimized with Monte Carlo simulations. Results were validated with a Cf-252 spectroscopic source, leading to expected detection efficiency of similar to 35% for neutrons with energy < 1MeV. Further development plans are discussed.
    PracovištěÚstav jaderné fyziky
    KontaktMarkéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228
    Rok sběru2023
Počet záznamů: 1  

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.