- Evaluating Pauses in Holter ECG Signals
Počet záznamů: 1  

Evaluating Pauses in Holter ECG Signals

  1. 1.
    SYSNO ASEP0555164
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevEvaluating Pauses in Holter ECG Signals
    Tvůrce(i) Plešinger, Filip (UPT-D) RID, ORCID, SAI
    Ivora, Adam (UPT-D)
    Halámek, Josef (UPT-D) RID, ORCID, SAI
    Viščor, Ivo (UPT-D) RID, ORCID, SAI
    Smíšek, Radovan (UPT-D) RID, ORCID, SAI
    Bulková, V. (CZ)
    Jurák, Pavel (UPT-D) RID, ORCID, SAI
    Celkový počet autorů7
    Číslo článku107
    Zdroj.dok.2021 Computing in Cardiology (CinC), 48. - New York : IEEE, 2021 - ISSN 2325-8861 - ISBN 978-166547916-5
    Poč.str.4 s.
    Forma vydáníOnline - E
    AkceComputing in Cardiology 2021 /48./
    Datum konání12.09.2021 - 15.09.2021
    Místo konáníBrno
    ZeměCZ - Česká republika
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.US - Spojené státy americké
    Klíč. slovaHolter ECG ; Evaluating Pauses
    Vědní obor RIVFS - Lékařská zařízení, přístroje a vybavení
    Obor OECDMedical engineering
    CEPFW01010305 GA TA ČR - Technologická agentura ČR
    Institucionální podporaUPT-D - RVO:68081731
    UT WOS000821955000202
    EID SCOPUS85124722290
    DOI https://doi.org/10.23919/CinC53138.2021.9662914
    AnotaceBackground: Information related to pauses in heart activity is an important output of ECG Holter monitoring reports. This information should be quickly assessed from inter-beat (RR) intervals only (a naïve approach). However, evaluating pauses in Holter ECGs recorded during usual daily activities can be more challenging due to signal lower quality. In this paper, we propose a method to improve pause detection in heart activity from Holter ECG recordings. Method: We used 978 recordings (length 45 seconds, 1-lead ECG, sampled at 200 or 250 Hz) with a known longest RR interval (from 1.12 to 19.0 seconds, mean duration of 2.72 ± 1.26 seconds). QRS complexes were detected by a convolutional neural network with a recurrent layer. This study started with the automated removal of suspicious QRS complexes by a QRS amplitude. Then we iterated through RR intervals, seeking saturated areas, missed QRS, or a strong noise, potentially, examined RR intervals were further refined. The longest interval was reported for each recording. Results: The ability to find life-threatening pauses improved from an F1 score of 0.95 to 0.97. Conclusion: The presented method improved pause detection in Holter ECG recordings compared to the naïve approach.
    PracovištěÚstav přístrojové techniky
    KontaktMartina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178
    Rok sběru2022
    Elektronická adresahttps://ieeexplore.ieee.org/document/9662914
Počet záznamů: 1  

Metadata v repozitáři ASEP jsou licencována pod licencí CC0.

  Tyto stránky využívají soubory cookies, které usnadňují jejich prohlížení. Další informace o tom jak používáme cookies.