Počet záznamů: 1
Evaluating Pauses in Holter ECG Signals
- 1.
SYSNO ASEP 0555164 Druh ASEP C - Konferenční příspěvek (mezinárodní konf.) Zařazení RIV D - Článek ve sborníku Název Evaluating Pauses in Holter ECG Signals Tvůrce(i) Plešinger, Filip (UPT-D) RID, ORCID, SAI
Ivora, Adam (UPT-D)
Halámek, Josef (UPT-D) RID, ORCID, SAI
Viščor, Ivo (UPT-D) RID, ORCID, SAI
Smíšek, Radovan (UPT-D) RID, ORCID, SAI
Bulková, V. (CZ)
Jurák, Pavel (UPT-D) RID, ORCID, SAICelkový počet autorů 7 Číslo článku 107 Zdroj.dok. 2021 Computing in Cardiology (CinC), 48. - New York : IEEE, 2021 - ISSN 2325-8861 - ISBN 978-166547916-5 Poč.str. 4 s. Forma vydání Online - E Akce Computing in Cardiology 2021 /48./ Datum konání 12.09.2021 - 15.09.2021 Místo konání Brno Země CZ - Česká republika Typ akce WRD Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova Holter ECG ; Evaluating Pauses Vědní obor RIV FS - Lékařská zařízení, přístroje a vybavení Obor OECD Medical engineering CEP FW01010305 GA TA ČR - Technologická agentura ČR Institucionální podpora UPT-D - RVO:68081731 UT WOS 000821955000202 EID SCOPUS 85124722290 DOI https://doi.org/10.23919/CinC53138.2021.9662914 Anotace Background: Information related to pauses in heart activity is an important output of ECG Holter monitoring reports. This information should be quickly assessed from inter-beat (RR) intervals only (a naïve approach). However, evaluating pauses in Holter ECGs recorded during usual daily activities can be more challenging due to signal lower quality. In this paper, we propose a method to improve pause detection in heart activity from Holter ECG recordings. Method: We used 978 recordings (length 45 seconds, 1-lead ECG, sampled at 200 or 250 Hz) with a known longest RR interval (from 1.12 to 19.0 seconds, mean duration of 2.72 ± 1.26 seconds). QRS complexes were detected by a convolutional neural network with a recurrent layer. This study started with the automated removal of suspicious QRS complexes by a QRS amplitude. Then we iterated through RR intervals, seeking saturated areas, missed QRS, or a strong noise, potentially, examined RR intervals were further refined. The longest interval was reported for each recording. Results: The ability to find life-threatening pauses improved from an F1 score of 0.95 to 0.97. Conclusion: The presented method improved pause detection in Holter ECG recordings compared to the naïve approach. Pracoviště Ústav přístrojové techniky Kontakt Martina Šillerová, sillerova@ISIBrno.Cz, Tel.: 541 514 178 Rok sběru 2022 Elektronická adresa https://ieeexplore.ieee.org/document/9662914
Počet záznamů: 1
