Calibration of the ITER outer vessel steady-state magnetic sensors

  1. 1.
    SYSNO ASEP0548224
    Druh ASEPJ - Článek v odborném periodiku
    Zařazení RIVJ - Článek v odborném periodiku
    Poddruh JČlánek ve WOS
    NázevCalibration of the ITER outer vessel steady-state magnetic sensors
    Tvůrce(i) Entler, Slavomír (UFP-V) ORCID
    Ďuran, Ivan (UFP-V) RID, ORCID
    Kocan, M. (FR)
    Vayakis, G. (FR)
    Sládek, Petr (UFP-V)
    Grover, Ondřej (UFP-V) ORCID
    Šebek, Josef (FZU-D) RID
    Výborný, Karel (FZU-D) RID, ORCID
    Celkový počet autorů8
    Číslo článku112398
    Zdroj.dok.Fusion Engineering and Design. - : Elsevier - ISSN 0920-3796
    Roč. 168, July (2021)
    Poč.str.6 s.
    Jazyk dok.eng - angličtina
    Země vyd.CH - Švýcarsko
    Klíč. slovaCalibration ; Hall sensors ; iter ; Magnetic diagnostics ; ovss
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    Vědní obor RIV – spolupráceFyzikální ústav - Fyzika plazmatu a výboje v plynech
    Způsob publikováníOmezený přístup
    Institucionální podporaUFP-V - RVO:61389021 ; FZU-D - RVO:68378271
    UT WOS000670075300004
    EID SCOPUS85101779562
    DOI10.1016/j.fusengdes.2021.112398
    AnotaceThe outer vessel steady-state magnetic field sensors (OVSS), a subsystem of the ITER magnetic diagnostics, consists of 60 units that will be installed on the vacuum vessel outer shell. Each OVSS unit features a pair of Hall sensors with a sensing layer made of bismuth and an onboard thermocouple. Prior to the installation of the sensors on ITER, OVSS will be subject to the complex calibration process designed to satisfy the ITER requirement for the measurement accuracy of 4 mT (2σ) in the range of the magnetic field from 0 to 2.5 T. The calibration process includes the calibration of the onboard thermocouple, sensor controller calibration, measurement of tilt of each Hall sensor with respect to the OVSS housing, and the measurement of the sensitivity of Hall sensors as a function of temperature and magnetic field for the range of ITER-relevant magnetic fields and temperatures. The expected calibration error projected to the magnetic field measurement of 2.5 mT will allow to meet the required measurement accuracy.