Počet záznamů: 1  

PHB/CHIT Scaffold as a Promising Biopolymer in the Treatment of Osteochondral Defects-An Experimental Animal Study

  1. 1.
    0542610 - FGÚ 2022 RIV CH eng J - Článek v odborném periodiku
    Petrovová, E. - Tomco, M. - Holovská, K. - Danko, J. - Krešáková, L. - Vdoviaková, K. - Simaiová, V. - Kolvek, F. - Horňáková, P. - Toth, T. - Zivcak, J. - Gal, P. - Sedmera, David - Luptáková, L. - Medvecký, L.
    PHB/CHIT Scaffold as a Promising Biopolymer in the Treatment of Osteochondral Defects-An Experimental Animal Study.
    Polymers. Roč. 13, č. 8 (2021), č. článku 1232. ISSN 2073-4360. E-ISSN 2073-4360
    Institucionální podpora: RVO:67985823
    Klíčová slova: biopolymer * cartilage * chitosan * regeneration * sheep model
    Obor OECD: Polymer science
    Impakt faktor: 4.967, rok: 2021
    Způsob publikování: Open access
    Web výsledku:
    https://www.mdpi.com/2073-4360/13/8/1232
    DOI: https://doi.org/10.3390/polym13081232

    Biopolymer composites allow the creation of an optimal environment for the regeneration of chondral and osteochondral defects of articular cartilage, where natural regeneration potential is limited. In this experimental study, we used the sheep animal model for the creation of knee cartilage defects. In the medial part of the trochlea and on the medial condyle of the femur, we created artificial defects (6 × 3 mm2) with microfractures. In four experimental sheep, both defects were subsequently filled with the porous acellular polyhydroxybutyrate/chitosan (PHB/CHIT)-based implant. Two sheep had untreated defects. We evaluated the quality of the newly formed tissue in the femoral trochlea defect site using imaging (X-ray, Computer Tomography (CT), Magnetic Resonance Imaging (MRI)), macroscopic, and histological methods. Macroscopically, the surface of the treated regenerate corresponded to the niveau of the surrounding cartilage. X-ray examination 6 months after the implantation confirmed the restoration of the contour in the subchondral calcified layer and the advanced rate of bone tissue integration. The CT scan revealed a low regenerative potential in the bone zone of the defect compared to the cartilage zone. The percentage change in cartilage density at the defect site was not significantly different to the reference area (0.06–6.4%). MRI examination revealed that the healing osteochondral defect was comparable to the intact cartilage signal on the surface of the defect. Hyaline-like cartilage was observed in most of the treated animals, except for one, where the defect was repaired with fibrocartilage. Thus, the acellular, chitosan-based biomaterial is a promising biopolymer composite for the treatment of chondral and osteochondral defects of traumatic character. It has potential for further clinical testing in the orthopedic field, primarily with the combination of supporting factors.