Počet záznamů: 1
Suppression of Penning discharges between the KATRIN spectrometers
- 1.
SYSNO ASEP 0532607 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Suppression of Penning discharges between the KATRIN spectrometers Tvůrce(i) Aker, M. (DE)
Altenmuller, K. (DE)
Beglarian, A. (DE)
Behrens, J. (DE)
Berlev, A. I. (RU)
Besserer, U. (DE)
Blaum, K. (DE)
Dragoun, Otokar (UJF-V) RID, SAI
Fedkevych, M. (DE)
Kovalík, Alojz (UJF-V) RID, ORCID, SAI
Lebeda, Ondřej (UJF-V) RID, ORCID, SAI
Ryšavý, Miloš (UJF-V) RID, ORCID, SAI
Vénos, Drahoslav (UJF-V) RID, SAI, ORCIDCelkový počet autorů 155 Číslo článku 821 Zdroj.dok. European Physical Journal C. - : Springer - ISSN 1434-6044
Roč. 80, č. 9 (2020)Poč.str. 12 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova KATRIN ; neutrino ; spectrometers Vědní obor RIV BG - Jaderná, atomová a mol. fyzika, urychlovače Obor OECD Particles and field physics CEP LM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LTT19005 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Open access Institucionální podpora UJF-V - RVO:61389005 UT WOS 000569786700005 EID SCOPUS 85090276093 DOI https://doi.org/10.1140/epjc/s10052-020-8278-y Anotace The KArlsruhe TRItium Neutrino experiment (KATRIN) aims to determine the effective electron (anti)-neutrino mass with a sensitivity of 0.2eV/c2 by precisely measuring the endpoint region of the tritium beta -decay spectrum. It uses a tandem of electrostatic spectrometers working as magnetic adiabatic collimation combined with an electrostatic (MAC-E) filters. In the space between the pre-spectrometer and the main spectrometer, creating a Penning trap is unavoidable when the superconducting magnet between the two spectrometers, biased at their respective nominal potentials, is energized. The electrons accumulated in this trap can lead to discharges, which create additional background electrons and endanger the spectrometer and detector section downstream. To counteract this problem, 'electron catchers' were installed in the beamline inside the magnet bore between the two spectrometers. These catchers can be moved across the magnetic-flux tube and intercept on a sub-ms time scale the stored electrons along their magnetron motion paths. In this paper, we report on the design and the successful commissioning of the electron catchers and present results on their efficiency in reducing the experimental background. Pracoviště Ústav jaderné fyziky Kontakt Markéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228 Rok sběru 2021 Elektronická adresa https://doi.org/10.1140/epjc/s10052-020-8278-y
Počet záznamů: 1