Počet záznamů: 1
Recent Results from Beam Tests of the ALPIDE Pixel Chip for the Upgrade of the ALICE Inner Tracker
- 1.
SYSNO ASEP 0522009 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Recent Results from Beam Tests of the ALPIDE Pixel Chip for the Upgrade of the ALICE Inner Tracker Tvůrce(i) Kushpil, Svetlana (UJF-V) RID, ORCID, SAI
Křížek, Filip (UJF-V) RID, ORCID, SAI
Isakov, Artem (UJF-V) ORCID, SAICelkový počet autorů 3 Číslo článku 8855021 Zdroj.dok. IEEE Transactions on Nuclear Science. - : Institute of Electrical and Electronics Engineers - ISSN 0018-9499
Roč. 66, č. 11 (2019), s. 2319-2323Poč.str. 5 s. Forma vydání Tištěná - P Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova A Large Ion Collider Experiment (ALICE) ; monolithic active pixel sensors (MAPS) ; tracking detectors Vědní obor RIV BF - Elementární částice a fyzika vys. energií Obor OECD Particles and field physics CEP LTT17018 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2015058 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy LM2015056 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy Způsob publikování Omezený přístup Institucionální podpora UJF-V - RVO:61389005 UT WOS 000516580100004 EID SCOPUS 85075710246 DOI https://doi.org/10.1109/TNS.2019.2945234 Anotace The planned upgrade of the A Large Ion Collider Experiment (ALICE) inner tracking system (ITS) aims at improving the ALICE performance in terms of spatial resolution and data rate readout. The new ITS will be a low-material-budget, high-granularity detector. It comprises seven concentric layers of monolithic active pixel sensors (MAPS), called ALPIDE, which are based on the TowerJazz 180-nm CMOS technology. In this article, we report on detection performance and radiation hardness studies of ALPIDE sensors. We show that these sensors keep having high detection efficiency for minimum ionizing particles (MIPs) (>99%) and low fake-hit rate while being radiation hard to some { 1.7} \times { 10}^{ 13}\,\,1 MeV \text{n}-{\text {eq}} cm-2 of nonionizing energy loss (NIEL) and 2.7 Mrad of total ionization dose (TID), which exceeds the expected radiation load during the detector lifetime ten times. ALPIDE sensors thus completely fulfill the design requirements. In addition, we show that measured cluster shape frequencies obtained at different operating points (thresholds, bias voltages) are well described with the state-of-the-art ALICE Monte Carlo simulation. Pracoviště Ústav jaderné fyziky Kontakt Markéta Sommerová, sommerova@ujf.cas.cz, Tel.: 266 173 228 Rok sběru 2020 Elektronická adresa https://doi.org/10.1109/TNS.2019.2945234
Počet záznamů: 1