Počet záznamů: 1
Prediction of Thiopurine Metabolite Levels Based on Haematological and Biochemical Parameters
- 1.
SYSNO ASEP 0512143 Druh ASEP J - Článek v odborném periodiku Zařazení RIV J - Článek v odborném periodiku Poddruh J Článek ve WOS Název Prediction of Thiopurine Metabolite Levels Based on Haematological and Biochemical Parameters Tvůrce(i) Hradsky, O. (CZ)
Potuznikova, K. (CZ)
Široká, Jitka (UEB-Q) ORCID
Lerchova, T. (CZ)
Urbánek, Lubor (UEB-Q) RID
Mihál, V. (CZ)
Spenerova, M. (CZ)
Velganova-Veghova, M. (CZ)
Karaskova, E. (CZ)
Bronsky, J. (CZ)Celkový počet autorů 10 Zdroj.dok. Journal of Pediatric Gastroenterology and Nutrition. - : Lippincott Williams & Wilkins - ISSN 0277-2116
Roč. 69, č. 4 (2019), e105-e110Poč.str. 6 s. Jazyk dok. eng - angličtina Země vyd. US - Spojené státy americké Klíč. slova 6-mercaptopurine ; 6-thioguanine ; azathioprine ; Crohn disease Vědní obor RIV CE - Biochemie Obor OECD Technologies involving the manipulation of cells, tissues, organs or the whole organism (assisted reproduction) Způsob publikování Open access Institucionální podpora UEB-Q - RVO:61389030 UT WOS 000506845100003 EID SCOPUS 85072193210 DOI https://doi.org/10.1097/MPG.0000000000002436 Anotace Objectives: Therapeutic drug monitoring of thiopurine erythrocyte levels is not available in all centers and it usually requires quite a long time to obtain the results. The aims of this study were to build a model predicting low levels of 6-thioguanine and 6-methylmercaptopurine in pediatric inflammatory bowel disease (IBD) patients and to build a model to predict nonadherence in patients treated with azathioprine (AZA). Methods: The study consisted of 332 observations in 88 pediatric IBD patients. Low AZA dosing was defined as 6-thioguanine levels <125 pmol/8 × 108 erythrocytes and 6-methylmercaptopurine levels <5700 pmol/8 × 108 erythrocytes. Nonadherence was defined as undetectable levels of 6-thioguanine and 6-methylmercaptopurine <240 pmol/8 × 108 erythrocytes. Data were divided into training and testing part. To construct the model predicting low 6-thioguanine levels, nonadherence, and the level of 6-thioguanine, the modification of random forest method with cross-validation and resampling was used. Results: The final models predicting low 6-thioguanine levels and nonadherence had area under the curve, 0.87 and 0.94, sensitivity, 0.81 and 0.82, specificity, 0.80 and 86, and distance, 0.31 and 0.21, respectively, when applied on the testing part of the dataset. When the final model for prediction of 6-thioguanine values was applied on testing dataset, a root-mean-square error of 110 was obtained. Conclusions: Using easily obtained laboratory parameters, we constructed a model with sufficient accuracy to predict patients with low 6-thioguanine levels and a model for prediction of AZA treatment nonadherence (web applications: https://hradskyo.shinyapps.io/6TG-prediction/ and https://hradskyo.shinyapps.io/Non-adherence/). Pracoviště Ústav experimentální botaniky Kontakt David Klier, knihovna@ueb.cas.cz, Tel.: 220 390 469 Rok sběru 2020 Elektronická adresa http://dx.doi.org/10.1097/MPG.0000000000002436
Počet záznamů: 1