Počet záznamů: 1  

DOUBLE code simulations of emissivities of fast neutrals for different plasma observation view-lines of neutral particle analyzers on the COMPASS tokamak

  1. 1.
    SYSNO ASEP0508697
    Druh ASEPC - Konferenční příspěvek (mezinárodní konf.)
    Zařazení RIVD - Článek ve sborníku
    NázevDOUBLE code simulations of emissivities of fast neutrals for different plasma observation view-lines of neutral particle analyzers on the COMPASS tokamak
    Tvůrce(i) Bogár, Klára (UFP-V) ORCID
    Tomeš, Matěj (UFP-V)
    Stöckel, Jan (UFP-V) RID
    Varju, Jozef (UFP-V) ORCID
    Stano, M. (SK)
    Celkový počet autorů5
    Číslo článku012009
    Zdroj.dok.Journal of Physics: Conference Series, 1046. - Bristol : IOP Publishing Ltd., 2018 - ISSN 1742-6588
    Rozsah stranroč. 992, č. 1 (2018)
    Poč.str.5 s.
    Forma vydáníOnline - E
    Akce20th International Summer School on Vacuum, Electron and Ion Technologies
    Datum konání25.09.2017 - 27.09.2017
    Místo konáníSozopol
    ZeměBG - Bulharsko
    Typ akceWRD
    Jazyk dok.eng - angličtina
    Země vyd.GB - Velká Británie
    Klíč. slovaDOUBLE ; COMPASS
    Vědní obor RIVBL - Fyzika plazmatu a výboje v plynech
    Obor OECDFluids and plasma physics (including surface physics)
    CEP8D15001 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    LM2015045 GA MŠMT - Ministerstvo školství, mládeže a tělovýchovy
    Institucionální podporaUFP-V - RVO:61389021
    UT WOS000445817300009
    EID SCOPUS85045761544
    DOI10.1088/1742-6596/992/1/012009
    AnotaceNeutral particle analyzers (NPA) measure line-integrated energy spectra of fast neutral atoms escaping the tokamak plasma, which are a product of charge-exchange (CX) collisions of plasma ions with background neutrals. They can observe variations in the ion temperature T i of non-thermal fast ions created by additional plasma heating. However, the plasma column which a fast atom has to pass through must be sufficiently short in comparison with the fast atom's mean-free-path. Tokamak COMPASS is currently equipped with one NPA installed at a tangential mid-plane port. This orientation is optimal for observing non-thermal fast ions. However, in this configuration the signal at energies useful for T i derivation is lost in noise due to the too long fast atoms' trajectories. Thus, a second NPA is planned to be connected for the purpose of measuring T i. We analyzed different possible view-lines (perpendicular mid-plane, tangential mid-plane, and top view) for the second NPA using the DOUBLE Monte-Carlo code and compared the results with the performance of the present NPA with tangential orientation. The DOUBLE code provides fast-atoms' emissivity functions along the NPA view-line. The position of the median of these emissivity functions is related to the location from where the measured signal originates. Further, we compared the difference between the real central T i used as a DOUBLE code input and the T iCX derived from the exponential decay of simulated energy spectra. The advantages and disadvantages of each NPA location are discussed.
    PracovištěÚstav fyziky plazmatu
    KontaktVladimíra Kebza, kebza@ipp.cas.cz, Tel.: 266 052 975
    Rok sběru2020
    Elektronická adresahttps://iopscience.iop.org/article/10.1088/1742-6596/992/1/012009/pdf
Počet záznamů: 1  